Payne Payne AHRI Furnace - PG80VTLB Gas furnace Repair, maintenance, and replacement planning
Payne PG80VTLB48090B** product image

Technical Specifications

Product Specs

  • AHRI unit role: Furnace
  • AHRI model/pattern: PG80VTLB48090B**
  • AHRI records represented: 100
  • AHRI equipment type: Central HP
  • AHRI tonnage: 1.9333333333333333
  • AHRI refrigerant: R-454B
  • Verified catalog model: PG80VTLB48090B
  • Verified product family: PG80VTLB
  • Verified catalog brand: Bryant, Payne
  • Catalog Model: PG80VTLB48090B
  • Manufacturer Number: PG80VTLB48090B
  • Catalog SKU: 1604089263577969
  • Catalog Brand: Bryant, Payne
  • Product Family: PG80VTLB
  • AFUE: 80
  • Air Flow Direction: Multi-Position
  • BTU Input: 58,000-88,000
  • BTU Output: 47,000-71,000
  • Blower Motor HP: 1/2
  • Blower Motor RPM: 1,200
  • Blower Motor Speeds: Variable
  • Blower Motor Type: ECM (Electronically Commutated Motor)
  • Blower Wheel Diameter: 8
  • Blower Wheel Width: 10"
  • Brand: Bryant, Payne
  • CFM: 340-1,480
  • CFM Heating: 1,045-1,240
  • Cabinet Width: 17.5
  • Color: Taupe
  • Country Of Origin: USA
  • Cycle/Hertz: 60 Hz
  • Energy Star Rated: NO
  • FER Compliant: YES
  • Filter Size: Contractor Supplied Based on Application
  • Fuel Type: Natural Gas
  • Full Load Amps: 6.7
  • Furnace Type: Gas
  • Gas Connection Size: 1/2"
  • Gas Connection Type: NPT
  • Height: 36
  • Ignition Type: Hot Surface (HSI)
  • Includes Filter Rack: NO
  • Length: 31
  • Maximum Overcurrent Protection (MOCP): 15
  • OPT Code: 1PPG80VTLB48090B
  • Phase: Single
  • Prop 65: YES
  • Stages Heating: 2
  • UPC: See Optical
  • Voltage: 115 VAC
  • Weight: 123
  • Width: 19

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 216733335

AHRI 216733335 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**2517AM*.

Eligible Central HP <5.4 tons

AHRI 216734005

AHRI 216734005 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3017AM*.

Eligible Central HP <5.4 tons

AHRI 216734538

AHRI 216734538 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3617AM*.

Eligible Central HP <5.4 tons

AHRI 216735080

AHRI 216735080 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3717AM*.

Eligible Central HP <5.4 tons

AHRI 216735657

AHRI 216735657 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3721AM*.

Eligible Central HP <5.4 tons

AHRI 216736436

AHRI 216736436 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*2412AM*.

Eligible Central HP <5.4 tons

AHRI 216737351

AHRI 216737351 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3012AM*.

Eligible Central HP <5.4 tons

AHRI 216738340

AHRI 216738340 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 217393923

AHRI 217393923 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ36AA3+TIC2025-0016 and indoor unit CSAH*4812AM*.

Eligible Central HP <5.4 tons

AHRI 217393997

AHRI 217393997 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ36AA3+TIC2025-0016 and indoor unit CSAH*4212AM*.

Loading more

Service planning

How GreenFlow handles PG80VTLB48090B** requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.