Heat Pump

Back to Carrier products

Carrier Heat Pump Crossover 48000 Btuh Heat Pump Condensing Unit R-454B (208/230-1)

Carrier Residential Heat Pump - 37MUHA Heat Pump Repair, maintenance, and replacement planning
Carrier Crossover 48000 Btuh Heat Pump Condensing Unit R-454B (208/230-1) product image

Technical Specifications

Product Specs

  • Model: 37MUHAQ48AA3
  • Manufacturer Number: 37MUHAQ48AA3
  • Vendor Number: 37MUHAQ48AA3
  • Catalog Brand: Carrier®, Bryant®, Payne®
  • Product Family: 37MUHA
  • AHRI Usage: Outdoor
  • Approvals: ETL Listed
  • Brand: Carrier®, Bryant®, Payne®
  • CFM: 712-1,600
  • Color: White
  • Compressor Type: Rotary
  • Condenser Fan CFM: 3037
  • Condenser Fan Discharge: Horizontal
  • Condenser Fan Motor Qty: 1
  • Condenser Motor Type: PSC (Permanent Split Capacitor)
  • Cooling Capacity: 48,000
  • Cooling Rated Capacity Btu/h: 50000
  • Country Of Origin: CHN
  • Cycle/Hertz: 60 Hz
  • EER2: 10.5-13.4
  • Energy Star Rated: NO
  • Heating Capacity: 57,300
  • Heating Capacity @ 5 Deg: 48000
  • Height: 38.39
  • High Heat: YES
  • Length: 16.34
  • Liquid Line Fitting Type: Flare
  • Liquid Line Size (OD): 3/8"
  • Maximum Overcurrent Protection (MOCP): 40
  • Maximum Piping Height: 98.43'
  • Maximum Piping Length: 246'
  • Metering Device: EEV - Electronic Expansion Valve
  • OPT Code: 1P37MUHAQ48AA3
  • Phase: Single
  • Prop 65: YES
  • Rated Load Amps (RLA): 21
  • Refrigerant: R-454B
  • Refrigerant Charge: 8.38 Lbs.
  • SEER2: 16.5-17.5
  • Stages Cooling: 1
  • Stages Heating: 1
  • Suction Line Fitting Type: Flare
  • Suction Line Size (OD): 3/4"
  • Tier: Performance™
  • Tonnage: 4
  • UPC: See Optical
  • Voltage: 208-230 VAC
  • Weight: 201.06
  • Width: 38.58

Useful troubleshooting details

  • Confirm the exact model number, serial number, installed equipment type, and site voltage before service or replacement planning.
  • Match replacement equipment and accessories against current Carrier compatibility requirements, refrigerant type, capacity, airflow, and local code requirements.

Service planning

How GreenFlow handles Crossover 48000 Btuh Heat Pump Condensing Unit R-454B (208/230-1) requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers