Heat Pump

Back to Carrier products

Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) service and support

Carrier Residential Heat Pump - 50VR-A Heat Pump Repair, maintenance, and replacement planning
Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) product image

Product service snapshot

Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) service details

Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) is a Carrier® heat pump record from the Carrier Enterprise catalog. Catalog model: 50VR-A60---3-TP. Product family: 50VR-A. Green Flow Solution uses this page for residential model identification, service planning, maintenance conversations, repair diagnostics, and replacement matching.

  • Brand: Carrier
  • Model or series: Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil)
  • Equipment type: Heat Pump
  • Product group: Residential Heat Pump - 50VR-A

Technical snapshot

Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) technical snapshot

Product Specs

  • Model: 50VR-A60---3-TP
  • Manufacturer Number: 50VR-A60---3-TP
  • Vendor Number: 50VR-A60---3-TP
  • Catalog Brand: Carrier®
  • Product Family: 50VR-A
  • AHRI Usage: Packaged
  • Air Flow Direction: Vertical
  • Approvals: UL Listed
  • Blower Motor HP: 1
  • Blower Motor RPM: 1,075
  • Blower Motor Speeds: Multiple
  • Blower Motor Type: ECM (Electronically Commutated Motor)
  • Blower Wheel Diameter: 11"
  • Blower Wheel Width: 10"
  • Brand: Carrier®
  • CFM: 1,750
  • COP: 3.5
  • Color: Gray
  • Compressor Type: Scroll
  • Condenser Coil Fins Per Inch (FPI): 21
  • Condenser Fan Blade Diameter: 26
  • Condenser Fan CFM: 3600
  • Condenser Fan Motor Qty: 1
  • Condenser Motor HP: 1/5
  • Condenser Motor RPM: 810
  • Condenser Motor Speeds: 1
  • Condenser Motor Type: PSC (Permanent Split Capacitor)
  • Cooling Capacity: 57,000
  • Cooling Rated Capacity Btu/h: 60000
  • Country Of Origin: MEX
  • Cubic Measurement: 70.5678
  • Cycle/Hertz: 60 Hz
  • Drain Connection Size: 3/4"
  • Drive Type: Direct
  • EER: 12
  • Electric Heat Range [kW]: 5-20
  • Energy Star Rated: NO
  • Evaporator Coil Fins Per Inch (FPI): 17
  • Evaporator Coil Metering Device: TXV/TEV - Thermostatic Expansion Valve
  • Full Load Amps: 1.2
  • HSPF: 8.5
  • Heating Capacity: 57,000
  • Height: 56.5
  • Length: 44.5
  • Locked Rotor Amps (LRA): 152.9
  • Maximum Overcurrent Protection (MOCP): 60
  • OPT Code: 1P50VR-A60---3-TP
  • Phase: Single
  • Prop 65: YES
  • Rated Load Amps (RLA): 16.2
  • Refrigerant: R-410A
  • Return Air Filter Size (RA) In Inches (W X H X D): 24 x 36 x 1
  • SEER: 15
  • Sound Level (dBA): 73
  • Stages Cooling: 2
  • Tier: Performance™
  • Tonnage: 5
  • UOM: EA
  • UPC: See Optical
  • Voltage: 208-230 VAC
  • Weight: 503
  • Width: 48.5

Useful troubleshooting details

  • Confirm the exact model number, serial number, installed equipment type, and site voltage before service or replacement planning.
  • Match replacement equipment and accessories against current Carrier compatibility requirements, refrigerant type, capacity, airflow, and local code requirements.

Service planning

How GreenFlow handles Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) service questions

Can GreenFlow help with Carrier Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) service requests?

Yes. GreenFlow can help collect the right details for Carrier Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) service requests, including the model, symptoms, equipment age, building type, access notes, photos, and timing.

What symptoms should I mention for Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil)?

Helpful symptoms include no heat, no cooling, weak airflow, defrost or outdoor icing concerns, auxiliary heat behavior, thermostat issues, short cycling, unusual noise, and whether the request is urgent or planned maintenance.

Is Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) used for residential or commercial properties?

Heat pump requests may come from homes, condos, multifamily properties, managed buildings, and light-commercial spaces depending on the system type and building layout.

What helps schedule Carrier® Performance™ - 5 Ton 15 SEER Residential Packaged Heat Pump Unit 2-Stage (Tin-Plated Indoor Coil) service faster?

Share the exact model and serial number if available, clear photos of the equipment and surrounding access area, current symptoms, recent maintenance history, and whether the request is repair, maintenance, or replacement planning.

Popular cities

Service Areas

Our Happy Customers