Technical Specifications

Product Specs

  • AHRI unit role: Indoor
  • AHRI model/pattern: CTF60C5CGS1
  • AHRI records represented: 120
  • AHRI equipment type: Central HP
  • AHRI tonnage: 3.75
  • AHRI refrigerant: R-454B
  • Verified catalog model: CTF60C5CGS1
  • Verified product family: CTF cased upflow/downflow aluminum indoor coil
  • Verified catalog brand: Coleman
  • Verified model family: CTF
  • AHRI indoor model/pattern: CTF60C5CGS1
  • Nominal capacity: 5 ton
  • Nominal cooling capacity: 60,000 BTU nominal cooling capacity
  • Configuration: Upflow/downflow
  • Coil type: full-cased MaxAlloy aluminum indoor coil
  • Metering device: TXV matched to outdoor component
  • Refrigerant: R-454B low-GWP compatible family
  • Published model dimension reference: 37.25Hx21Wx21.5D
  • Cabinet code: C
  • Slab code: G
  • Brand family page: https://www.colemanac.com/residential-equipment/heating-and-cooling/evaporator-coils/ctf_col_ds/ctf-600-2000-cfm-cased-upflow-downflow-indoor-coil
  • YorkNow model reference: https://www.yorknow.com/ctf60c5cgs1.html
  • Technical guide: https://www.yorknow.com/pub/media/documentation/ctm_techguide.pdf

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 214396562

AHRI 214396562 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Eligible Central HP <5.4 tons

AHRI 214396567

AHRI 214396567 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Eligible Central HP <5.4 tons

AHRI 214396572

AHRI 214396572 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Eligible Central HP <5.4 tons

AHRI 214396577

AHRI 214396577 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Eligible Central HP <5.4 tons

AHRI 214396614

AHRI 214396614 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Eligible Central HP <5.4 tons

AHRI 214397010

AHRI 214397010 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Eligible Central HP <5.4 tons

AHRI 214397045

AHRI 214397045 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Eligible Central HP <5.4 tons

AHRI 214397090

AHRI 214397090 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Eligible Central HP <5.4 tons

AHRI 214397397

AHRI 214397397 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Eligible Central HP <5.4 tons

AHRI 214397419

AHRI 214397419 identifies a Mass Save qualified Central HP <5.4 tons from COLEMAN with outdoor unit HH860E2S11 and indoor unit CTF60C5CGS1.

Loading more

Service planning

How GreenFlow handles CTF60C5CGS1 requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers