VRF outdoor unit

Back to Bryant products

Bryant VRF outdoor unit 38VMR Heat Recovery Outdoor Unit

Bryant VRF and commercial HVAC VRF outdoor unit Repair, maintenance, and replacement planning
Bryant 38VMR Heat Recovery Outdoor Unit product image

Technical Specifications

Product Specs

  • Available in 6 – 28 ton non modular design
  • Industries most compact 20 ton VRF system
  • Ability to connect up to 64 indoor units
  • 2-pipe heat recovery system
  • High performance outdoor units with all inverter driven scroll compressor
  • DC inverter condenser fan motor
  • 208/230-3-60Hz or 460-3-60Hz voltage
  • Cooling ambient operating temperature is 14⁰ F to 122⁰ F and heating ambient operating temperature is -13⁰ F to 60⁰ F
  • Connected capacity is up to 150%
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements
  • Unit performance is in accordance with AHRI 1230 standards
  • Brand: Bryant
  • Model or series: 38VMR Heat Recovery Outdoor Unit
  • Equipment type: VRF outdoor unit
  • Product group: VRF and commercial HVAC
  • System role: Variable refrigerant flow system equipment
  • Application: Commercial, light-commercial, or managed-building HVAC and water-heating applications
  • Compatibility check: Match with compatible indoor unit, coil or air handler, controls, refrigerant, voltage, and capacity.
  • Verified source: bryant.com

Useful troubleshooting details

  • Confirm the packaged unit model, serial number, tonnage, voltage, refrigerant or fuel type, control setup, access location, and service history.
  • Share no-heat, no-cooling, weak airflow, alarms, control issues, tenant comfort complaints, condensate, or unusual noise.
  • For planning, include business hours, rooftop or mechanical access notes, tenant impact, replacement timing, and maintenance history.

Service planning

How GreenFlow handles 38VMR Heat Recovery Outdoor Unit requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers