Furnace
Airquest N96MSN0401410A
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Exact model
- Certifications
- 17 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 96 %
Matched systems
Certificates
16 verified catalog relationships.
AHRI 216733428
AHRI 216733428 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK and indoor unit EA*5X25M17A*.
AHRI 216735173
AHRI 216735173 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK and indoor unit EA*5X37M17A*.
AHRI 217632887
AHRI 217632887 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X24M14A*.
AHRI 217633031
AHRI 217633031 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X24M17A*.
AHRI 217633211
AHRI 217633211 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X25M17A*.
AHRI 217633318
AHRI 217633318 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X30M14A*.
AHRI 217633462
AHRI 217633462 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X30M17A*.
AHRI 217633642
AHRI 217633642 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X36M17A*.
Source-backed diagnostics
Error codes
32 codes matched to Airquest N96MSN0401410A through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout - after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.