Furnace
Airquest N96MSN1002122A
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Exact model
- Certifications
- 31 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 96.3 %
Matched systems
Certificates
30 verified catalog relationships.
AHRI 214158730
AHRI 214158730 identifies a HP - Split System from Airquest with outdoor unit H5H6S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 214202572
AHRI 214202572 identifies a HP - Split System from Airquest with outdoor unit N5H5S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 214202573
AHRI 214202573 identifies a HP - Split System from Airquest with outdoor unit R5H5S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 216677355
AHRI 216677355 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CURAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216735852
AHRI 216735852 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216738593
AHRI 216738593 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH24AAK and indoor unit ESH5X36M12A*.
AHRI 217395129
AHRI 217395129 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit ESH5X42M12A*.
AHRI 217396645
AHRI 217396645 identifies a Mass Save qualified HP - Split System from Airquest with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit EA*5X43M21A*.
Source-backed diagnostics
Error codes
32 codes matched to Airquest N96MSN1002122A through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout - after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.