Product troubleshooting
Back to American Standard S9V2B060U4VS***
American Standard S9V2B060U4VS*** troubleshooting and error codes
These codes are matched from manufacturer documentation to this model's series or control platform. Keep checks visible and safe; do not open electrical, refrigerant, gas, combustion, or sealed equipment compartments.
Source-backed code set
23 matched codes
| Code | Meaning | System area | Priority |
|---|---|---|---|
| E01 | Internal furnace-control failure | System diagnostics | Urgent |
| E2.1 | Retry exceeded; flame never sensed | System diagnostics | Service |
| E2.2 | Recycle limit exceeded; flame sensed then lost | System diagnostics | Urgent |
| E2.3 | First-stage gas valve not energized when required | System diagnostics | Service |
| E3.1 | First-stage pressure switch shorted | System diagnostics | Urgent |
| E3.2 | First-stage pressure switch open | System diagnostics | Urgent |
| E3.3 | Second-stage pressure switch shorted | System diagnostics | Urgent |
| E3.4 | Second-stage pressure switch open | System diagnostics | Urgent |
| E04 | Limit circuit open | System diagnostics | Urgent |
| E05 | Flame detected when it should not be present | System diagnostics | Service |
| E6.1 | Line-voltage polarity reversed | System diagnostics | Urgent |
| E6.2 | Bad grounding | System diagnostics | Service |
| E6.3 | Igniter relay failure or open igniter | System diagnostics | Urgent |
| E7.1 | First-stage gas valve energized when it should be off | System diagnostics | Service |
| E08 | Low flame current | System diagnostics | Urgent |
| E09 | Inducer limit switch or condensate pressure switch open | System diagnostics | Urgent |
| E11 | Gas-valve operating fault | System diagnostics | Urgent |
| E12 | Control fuse open | System diagnostics | Urgent |
| E13 | Blower horsepower or OEM identification mismatch | System diagnostics | Urgent |
| E14 | Personality module or local configuration data unavailable | System diagnostics | Service |
| E15 | Personality module and local unit data corrupt | System diagnostics | Service |
| E17 | No blower-motor communication response | System diagnostics | Urgent |
| E18 | Blower communication failure at the control | System diagnostics | Urgent |
No matching error codes found.