Heat pump condensing unit

Back to Bryant products

Bryant Heat pump condensing unit 248TAN036**AA*

Bryant Bryant AHRI Outdoor - 248TAN Heat pump condensing unit Repair, maintenance, and replacement planning
Bryant 248TAN036**AA* product image

Technical Specifications

Product Specs

  • AHRI unit role: Outdoor
  • AHRI model/pattern: 248TAN036**AA*
  • AHRI records represented: 271
  • AHRI equipment type: HP - Split System
  • AHRI refrigerant: R-454B
  • Verified catalog model: 248TAN03600A
  • Verified product family: 248TAN
  • Verified catalog brand: Bryant
  • Catalog Model: 248TAN03600A
  • Manufacturer Number: 248TAN03600A
  • Catalog SKU: 1604089257792108
  • Catalog Brand: Bryant
  • Product Family: 248TAN
  • Tonnage: 3
  • SEER2: 17
  • Refrigerant: R-454B
  • Approvals: UL Listed
  • Brand: Bryant
  • CFM: 965
  • Color: Brown
  • Compressor Type: Scroll
  • Condenser Coil Fins Per Inch (FPI): 20
  • Condenser Fan Blade Diameter: 26
  • Condenser Fan CFM: 3788
  • Condenser Fan Discharge: Vertical
  • Condenser Fan Motor Qty: 1
  • Condenser Motor HP: 1/3
  • Condenser Motor RPM: 700
  • Condenser Motor Speeds: 1
  • Condenser Motor Type: ECM (Electronically Commutated Motor)
  • Cooling Capacity: 33,200-37,600
  • Cooling Rated Capacity Btu/h: 36000
  • Country Of Origin: USA
  • Cycle/Hertz: 60 Hz
  • EER2: 14
  • Energy Star Rated: YES
  • Full Load Amps: 2.6
  • Height: 38.875
  • Inverter: NO
  • Length: 35
  • Liquid Line Fitting Type: Sweat or Braze
  • Liquid Line Size (OD): 3/8"
  • Locked Rotor Amps (LRA): 90
  • Maximum Overcurrent Protection (MOCP): 40
  • Metering Device: TXV/TEV - Thermostatic Expansion Valve
  • OPT Code: 1P248TAN03600A
  • Phase: Single
  • Prop 65: YES
  • Rated Load Amps (RLA): 18.5
  • Sound Level (dBA): 66-68
  • Stages Cooling: 2
  • Stages Heating: 2
  • Suction Line Fitting Type: Sweat or Braze
  • Suction Line Size (OD): 7/8"
  • Tier: Preferred
  • UPC: See Optical
  • Voltage: 208-230 VAC
  • Weight: 260
  • Width: 35

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
ENERGY STAR certified HP - Split System

AHRI 215560681

AHRI 215560681 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit FT5AN(B,X)C36L*.

ENERGY STAR certified HP - Split System

AHRI 215560682

AHRI 215560682 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit FG5ANXC36L*.

ENERGY STAR certified HP - Split System

AHRI 215560683

AHRI 215560683 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit PF5TNXC36L*.

ENERGY STAR certified HP - Split System

AHRI 215619449

AHRI 215619449 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4821XMA*.

ENERGY STAR certified HP - Split System

AHRI 215619489

AHRI 215619489 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4821XMA*.

ENERGY STAR certified HP - Split System

AHRI 215619502

AHRI 215619502 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4821XMA*.

ENERGY STAR certified HP - Split System

AHRI 215619515

AHRI 215619515 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4821XMA*.

ENERGY STAR certified HP - Split System

AHRI 215619534

AHRI 215619534 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4821XMA*.

ENERGY STAR certified HP - Split System

AHRI 215619640

AHRI 215619640 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4821XMA*.

ENERGY STAR certified HP - Split System

AHRI 215619670

AHRI 215619670 identifies a Mass Save qualified HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4821XMA*.

Loading more

Service planning

How GreenFlow handles 248TAN036**AA* requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Additional Services

Brands We Service

Popular cities

Service Areas

Our Happy Customers