Technical Specifications

Product Specs

  • AHRI unit role: Outdoor
  • AHRI model/pattern: 249VAN060**AA*
  • AHRI records represented: 217
  • AHRI equipment type: Central HP
  • AHRI tonnage: 4.791666666666667
  • AHRI refrigerant: R-454B
  • Verified catalog model: 249VAN06000A
  • Verified product family: 249VAN
  • Verified catalog brand: Bryant
  • Catalog Model: 249VAN06000A
  • Manufacturer Number: 249VAN06000A
  • Catalog SKU: 1604089271489020
  • Catalog Brand: Bryant
  • Product Family: 249VAN
  • Tonnage: 5
  • SEER2: 19
  • Refrigerant: R-454B
  • Brand: Bryant
  • CFM: 5,000
  • Color: Taupe
  • Compressor Type: Rotary
  • Condenser Coil Fins Per Inch (FPI): 20
  • Condenser Fan Blade Diameter: 26
  • Condenser Fan CFM: 5000
  • Condenser Fan Discharge: Vertical
  • Condenser Fan Motor Qty: 1
  • Condenser Motor HP: 1/3
  • Condenser Motor RPM: 200-800
  • Condenser Motor Speeds: Variable
  • Condenser Motor Type: ECM (Electronically Commutated Motor)
  • Cooling Capacity: 66
  • Cooling Rated Capacity Btu/h: 60000
  • Country Of Origin: USA
  • Cycle/Hertz: 60 Hz
  • EER2: 14
  • Energy Star Rated: YES
  • Full Load Amps: 0.88
  • HSPF2: 10
  • Heating Capacity: 60.5
  • Height: 45.6875
  • Inverter: YES
  • Length: 35
  • Liquid Line Fitting Type: Sweat or Braze
  • Liquid Line Size (OD): 3/8"
  • Maximum Overcurrent Protection (MOCP): 40
  • Metering Device: EEV - Electronic Expansion Valve
  • OPT Code: 1P249VAN06000A
  • Phase: Single
  • Prop 65: YES
  • Rated Load Amps (RLA): 20.1
  • Sound Level (dBA): 73
  • Stages Cooling: Variable
  • Stages Heating: Variable
  • Suction Line Fitting Type: Sweat or Braze
  • Suction Line Size (OD): 1 1/8"
  • Tier: Preferred
  • UPC: See Optical
  • Voltage: 208-230 VAC
  • Weight: 304
  • Width: 35

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 217918382

AHRI 217918382 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit FT5ANBD60L*.

Eligible Central HP <5.4 tons

AHRI 217918383

AHRI 217918383 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit FG5ANBD60L*.

Eligible Central HP <5.4 tons

AHRI 217918384

AHRI 217918384 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit PF5TNBD60L*.

Eligible Central HP <5.4 tons

AHRI 217931462

AHRI 217931462 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit CAA**6024AM*.

Eligible Central HP <5.4 tons

AHRI 217931492

AHRI 217931492 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit CAA**6024AM*.

Eligible Central HP <5.4 tons

AHRI 217931507

AHRI 217931507 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit CAA**6024AM*.

Eligible Central HP <5.4 tons

AHRI 217931537

AHRI 217931537 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit CAA**6024AM*.

Eligible Central HP <5.4 tons

AHRI 217931612

AHRI 217931612 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit CAA**6024AM*.

Eligible Central HP <5.4 tons

AHRI 217931627

AHRI 217931627 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit CAA**6024AM*.

Eligible Central HP <5.4 tons

AHRI 217931658

AHRI 217931658 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 249VAN060**AA* and indoor unit CAA**6024AM*.

Loading more

Service planning

How GreenFlow handles 249VAN060**AA* requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Additional Services

Brands We Service

Popular cities

Service Areas

Our Happy Customers