Technical Specifications

Product Specs

  • AHRI unit role: Outdoor
  • AHRI model/pattern: 37MUHAQ60AA3
  • AHRI records represented: 18
  • AHRI equipment type: Central HP
  • AHRI tonnage: 4.5
  • AHRI refrigerant: R-454B
  • Verified catalog model: 37MUHAQ60AA3
  • Verified product family: 37MUHA
  • Verified catalog brand: Carrier, Bryant
  • Catalog Model: 37MUHAQ60AA3
  • Manufacturer Number: 37MUHAQ60AA3
  • Catalog SKU: 1604089257813507
  • Catalog Brand: Carrier, Bryant
  • Product Family: 37MUHA
  • Tonnage: 5
  • SEER2: 17.5
  • Refrigerant: R-454B
  • Approvals: ETL Listed
  • Brand: Carrier, Bryant
  • CFM: 712-1,800
  • Color: White
  • Compressor Type: Rotary
  • Condenser Coil Fins Per Inch (FPI): 20
  • Condenser Fan Blade Diameter: 20.9
  • Condenser Fan CFM: 2649
  • Condenser Fan Discharge: Horizontal
  • Condenser Fan Motor Qty: 1
  • Condenser Motor HP: 1/8
  • Condenser Motor RPM: 1,000
  • Condenser Motor Speeds: 4
  • Condenser Motor Type: PSC (Permanent Split Capacitor)
  • Cooling Capacity: 11,400-60,000
  • Cooling Rated Capacity Btu/h: 11400
  • Country Of Origin: CHN
  • Cycle/Hertz: 60 Hz
  • EER2: 12
  • Energy Star Rated: YES
  • Full Load Amps: 1.2
  • Heating Capacity: 8,100-64,500
  • Heating Capacity @ 5 Deg: 54000
  • Height: 52.48
  • High Heat: YES
  • Length: 16.34
  • Liquid Line Fitting Type: Flare
  • Liquid Line Size (OD): 3/8"
  • Maximum Overcurrent Protection (MOCP): 40
  • Maximum Piping Height: 98.4'
  • Maximum Piping Length: 246
  • Metering Device: EEV - Electronic Expansion Valve
  • OPT Code: 1P37MUHAQ60AA3
  • Phase: Single
  • Prop 65: YES
  • Rated Current Amps (RCA): 7.47
  • Rated Load Amps (RLA): 7.47
  • Refrigerant Charge: 11.46
  • Sound Level (dBA): 65
  • Stages Cooling: 1
  • Stages Heating: 1
  • Suction Line Fitting Type: Flare
  • Suction Line Size (OD): 3/4"
  • Tier: Performance
  • UPC: See Optical
  • Voltage: 208-230 VAC
  • Weight: 240.08
  • Width: 37.48

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 215318781

AHRI 215318781 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit 45MUAAQ60XX3.

Eligible Central HP <5.4 tons

AHRI 215318782

AHRI 215318782 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit 45MUHAQ60XX3.

Eligible Central HP <5.4 tons

AHRI 217456336

AHRI 217456336 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit 45MULAQ60XMX.

Eligible Central HP <5.4 tons

AHRI 217456337

AHRI 217456337 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit 45MULAQ60XDX.

Eligible Central HP <5.4 tons

AHRI 217495491

AHRI 217495491 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit H,PG48*60+TXV+TD.

Eligible Central HP <5.4 tons

AHRI 217557340

AHRI 217557340 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit D5FUHAH60XAK.

Eligible Central HP <5.4 tons

AHRI 217889375

AHRI 217889375 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit PL60H210P29*+TXV+TD.

Eligible Central HP <5.4 tons

AHRI 217889380

AHRI 217889380 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit V,C48H175P38*+TXV+TD.

Eligible Central HP <5.4 tons

AHRI 217889381

AHRI 217889381 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit PL60H210P17*+TXV+TD.

Eligible Central HP <5.4 tons

AHRI 217889382

AHRI 217889382 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT with outdoor unit 37MUHAQ60AA3 and indoor unit V,C60H210P17*+TXV+TD.

Loading more

Service planning

How GreenFlow handles 37MUHAQ60AA3 requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers