Technical Specifications

Product Specs

  • AHRI unit role: Outdoor
  • AHRI model/pattern: 37MVRAQ09AA3
  • AHRI records represented: 2
  • AHRI equipment type: Mini/Multi Split
  • AHRI tonnage: 0.75
  • AHRI refrigerant: R-454B
  • Verified catalog model: 37MVRAQ09AA3
  • Verified product family: 37MVRA
  • Verified catalog brand: Carrier, Bryant
  • Catalog Model: 37MVRAQ09AA3
  • Manufacturer Number: 37MVRAQ09AA3
  • Catalog SKU: 1604089258179865
  • Catalog Brand: Carrier, Bryant
  • Product Family: 37MVRA
  • Tonnage: 0.75
  • SEER2: 19
  • Refrigerant: R-454B
  • Approvals: UL Listed
  • Brand: Carrier, Bryant
  • CFM: 176-312
  • Color: White
  • Compressor Type: Rotary
  • Condenser Fan CFM: 1059
  • Condenser Motor HP: 1/25
  • Condenser Motor RPM: 800
  • Condenser Motor Speeds: 2
  • Condenser Motor Type: PSC (Permanent Split Capacitor)
  • Cooling Capacity: 9,000
  • Cooling Rated Capacity Btu/h: 9000
  • Country Of Origin: CHN
  • Cycle/Hertz: 60 Hz
  • EER2: 10.9
  • Energy Star Rated: NO
  • Heating Capacity: 10,000-12,400
  • Heating Capacity @ 5 Deg: 7000
  • Height: 19.49
  • High Heat: NO
  • Length: 10.63
  • Liquid Line Fitting Type: Flare
  • Liquid Line Size (OD): 1/4"
  • Maximum Overcurrent Protection (MOCP): 15
  • Maximum Piping Height: 49.21'
  • Maximum Piping Length: 82.02'
  • Metering Device: Capillary Tube
  • Number Of HVAC Zones: 1
  • OPT Code: 1P37MVRAQ09AA3
  • Phase: Single
  • Prop 65: YES
  • Rated Current Amps (RCA): 0.48
  • Rated Load Amps (RLA): 2.4
  • Refrigerant Charge: 1.28 Lbs.
  • Stages Cooling: 1
  • Stages Heating: 1
  • Suction Line Fitting Type: Flare
  • Suction Line Size (OD): 3/8"
  • Tier: Standard
  • UPC: See Optical
  • Voltage: 208-230 VAC
  • Weight: 51.59
  • Width: 28.35

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Service planning

How GreenFlow handles 37MVRAQ09AA3 requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers