Gas furnace

Back to Bryant products

Bryant Gas furnace 82*SB48090V17***

Bryant Bryant AHRI Furnace - 820SB Gas furnace Repair, maintenance, and replacement planning
Bryant 82*SB48090V17*** product image

Technical Specifications

Product Specs

  • AHRI unit role: Furnace
  • AHRI model/pattern: 82*SB48090V17***
  • AHRI records represented: 195
  • AHRI equipment type: Central HP
  • AHRI tonnage: 1.9333333333333333
  • AHRI refrigerant: R-454B
  • Verified catalog model: 820SB48090V17
  • Verified product family: 820SB
  • Verified catalog brand: Bryant
  • Verified AHRI-to-catalog mapping: 82*SB48090V17*** -> 820SB48090V17
  • Verified model family: 820SB
  • Equipment type: Gas furnace
  • Application: matched furnace for split-system air conditioner or heat pump combinations
  • Catalog Model: 820SB48090V17
  • Manufacturer Number: 820SB48090V17
  • Catalog SKU: 1604089231836733
  • Catalog Brand: Bryant
  • Product Family: 820SB
  • AFUE: 80
  • Air Flow Direction: Multi-Position
  • BTU Input: 88,000
  • BTU Output: 71,000
  • Blower Motor HP: 1/2
  • Blower Motor Speeds: Variable
  • Blower Motor Type: ECM (Electronically Commutated Motor)
  • Blower Wheel Diameter: 10"
  • Blower Wheel Width: 8"
  • Brand: Bryant
  • CFM: 340-1,480
  • CFM Heating: 1,220
  • Cabinet Width: 17.5
  • Color: Taupe
  • Country Of Origin: USA
  • Cycle/Hertz: 60 Hz
  • Energy Star Rated: NO
  • FER Compliant: NO
  • Filter Size: Contractor Supplied Based on Application
  • Fuel Type: Natural Gas
  • Full Load Amps: 6.7
  • Furnace Type: Gas
  • Gas Connection Size: 1/2"
  • Gas Connection Type: NPT
  • Height: 33.3333
  • Ignition Type: Hot Surface (HSI)
  • Includes Filter Rack: NO
  • Length: 29
  • Maximum Overcurrent Protection (MOCP): 15
  • OPT Code: 1P820SB48090V17
  • Phase: Single
  • Prop 65: YES
  • Stages Heating: 1
  • Tier: Preferred
  • UPC: See Optical
  • Voltage: 115 VAC
  • Weight: 134
  • Width: 17.5

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 216733243

AHRI 216733243 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**2517AM*.

Eligible Central HP <5.4 tons

AHRI 216733913

AHRI 216733913 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3017AM*.

Eligible Central HP <5.4 tons

AHRI 216734446

AHRI 216734446 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3617AM*.

Eligible Central HP <5.4 tons

AHRI 216734988

AHRI 216734988 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3717AM*.

Eligible Central HP <5.4 tons

AHRI 216735525

AHRI 216735525 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3721AM*.

Eligible Central HP <5.4 tons

AHRI 216736295

AHRI 216736295 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*2412AM*.

Eligible Central HP <5.4 tons

AHRI 216737174

AHRI 216737174 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3012AM*.

Eligible Central HP <5.4 tons

AHRI 216738163

AHRI 216738163 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 217191727

AHRI 217191727 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit D(A,C,E)30A3J+TDR.

Eligible Central HP <5.4 tons

AHRI 217191728

AHRI 217191728 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit D(A,C,E)36A3J+TDR.

Loading more

Service planning

How GreenFlow handles 82*SB48090V17*** requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers