Furnace
Bryant 926TC30040V14*D
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Model pattern
- Certifications
- 80 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 95 %
Matched systems
Certificates
79 verified catalog relationships.
AHRI 215643522
AHRI 215643522 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN024**AA* and indoor unit CAA**2414AM*.
AHRI 215643525
AHRI 215643525 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN524**AA* and indoor unit CAA**2414AM*.
AHRI 215643527
AHRI 215643527 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH8TAN524**AA* and indoor unit CAA**2414AM*.
AHRI 215644169
AHRI 215644169 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN024**AA* and indoor unit CAA**2417AM*.
AHRI 215644171
AHRI 215644171 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN524**AA* and indoor unit CAA**2417AM*.
AHRI 215644172
AHRI 215644172 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH8TAN524**AA* and indoor unit CAA**2417AM*.
AHRI 215644966
AHRI 215644966 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN024**AA* and indoor unit CAA**2517AM*.
AHRI 215644967
AHRI 215644967 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN524**AA* and indoor unit CAA**2517AM*.
Source-backed diagnostics
Error codes
45 codes matched to Bryant 926TC30040V14*D through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.