Furnace
Bryant 926TC60080V21*D
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Model pattern
- Certifications
- 154 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 95 %
Matched systems
Certificates
153 verified catalog relationships.
AHRI 215617733
AHRI 215617733 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN024**AA* and indoor unit CVAVA3621XMA*.
AHRI 215617734
AHRI 215617734 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN524**AA* and indoor unit CVAVA3621XMA*.
AHRI 215617735
AHRI 215617735 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH8TAN524**AA* and indoor unit CVAVA3621XMA*.
AHRI 215618503
AHRI 215618503 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN024**AA* and indoor unit CVAVA3721XMA*.
AHRI 215618504
AHRI 215618504 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN524**AA* and indoor unit CVAVA3721XMA*.
AHRI 215618505
AHRI 215618505 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH8TAN524**AA* and indoor unit CVAVA3721XMA*.
AHRI 215619823
AHRI 215619823 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4821XMA*.
AHRI 215619824
AHRI 215619824 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN536**AA* and indoor unit CVAMA4821XMA*.
Source-backed diagnostics
Error codes
45 codes matched to Bryant 926TC60080V21*D through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.