Bryant 926TC60100V21 troubleshooting and error codes

These codes are matched from manufacturer documentation to this model's series or control platform. Keep checks visible and safe; do not open electrical, refrigerant, gas, combustion, or sealed equipment compartments.

Source-backed code set

45 matched codes

CodeMeaningSystem areaPriority
10.1L1 polarity faultLine power / polarityUrgent
12.1W on at power upThermostat input / startupService
13.1Limit lockout - switch open longer than 3 minutes in Main Limit circuitMain limit circuitUrgent
14.1Ignition lockout after 4 consecutive ignition triesIgnition / flame provingUrgent
14.2Flame lost 3 times after 70s of heatingFlame sensingUrgent
14.3Lockout - 7 loss of flame events during a heat requestFlame sensingUrgent
14.4Lockout - 7 LPS open circuits during a heat requestMain pressure switchUrgent
15.1Lockout - no blower RPM detectedIndoor blowerUrgent
19.1InteliSense communications lossInteliSense communicationsService
21.124VAC sensed on gas valve when it should not beGas valve circuitUrgent
22.1False flameFlame sensingUrgent
23.4LPS stuck closedMain pressure switchUrgent
23.5HPS stuck closedHigh-heat pressure switchUrgent
24.1Fuse faultLow-voltage control circuitUrgent
25.1No program info in micro, no heating operationFurnace control programmingUrgent
25.2Corrupted program file, no heating operationFurnace control programmingUrgent
25.3Twinned units are not identical; program numbers do not matchTwinning / control programmingUrgent
25.4Main program invalid, using backup program to operateFurnace control programmingService
25.5Installer settings corruptedFurnace control settingsService
25.6Wrong program for control usedFurnace control programmingUrgent
25.7Non-condensing program detected in a condensing modelFurnace control programmingUrgent
27.1Program in super plug is missingControl programming accessoryUrgent
27.2Program in super plug is not recognized or corruptedControl programming accessoryUrgent
27.3Super plug programming failedControl programming accessoryUrgent
31.1Open secondary pressure switch (HPS)High-heat pressure switchUrgent
31.3High Heat Only or next-cycle HPS failed to closeHigh-heat pressure switchUrgent
32.1Open Main pressure switch (LPS)Main pressure switchUrgent
33.1A switch has opened in the Main Limit circuitMain limit circuitUrgent
33.2Lockout - High Heat Only for current cycleMain limit circuitUrgent
34.1Ignition fault during four consecutive ignition trialsIgnition / flame provingUrgent
34.5Low heat flame lost before on-delayFlame sensingUrgent
34.6Low heat flame lost after on-delayFlame sensingUrgent
34.7High heat flame lost before on-delayFlame sensingUrgent
34.8High heat flame lost after on-delayFlame sensingUrgent
34.9No blower RPM at start upIndoor blowerUrgent
41.1No RPM from blower motor while runningIndoor blowerUrgent
43.1HPS closed before LPSPressure switchesUrgent
45.1Internal control errorFurnace control boardUrgent
45.2GVR relay not closingFurnace control board / gas valve relayUrgent
45.3Micro EEPROM errorFurnace control boardUrgent
46.1Momentary loss of powerElectrical supplyNotice
52.1SAT - OpenSupply-air temperature sensorService
52.2SAT - ShortSupply-air temperature sensorService
53.1RAT - OpenReturn-air temperature sensorService
53.2RAT - ShortReturn-air temperature sensorService