Furnace
Bryant 926TC66100V21
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Exact model
- Certifications
- 201 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 96.2 %
Matched systems
Certificates
200 verified catalog relationships.
AHRI 213208922
AHRI 213208922 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH5SAN436**AA* and indoor unit CAP**3721AL*.
AHRI 214142857
AHRI 214142857 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 235SAN036**AA* and indoor unit CAA**4821AM*.
AHRI 214142858
AHRI 214142858 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 246SAN036**AA* and indoor unit CAA**4821AM*.
AHRI 214142859
AHRI 214142859 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH5SAN536**AA* and indoor unit CAA**4821AM*.
AHRI 214142860
AHRI 214142860 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH5SAN536**AA* and indoor unit CAA**4821AM*.
AHRI 214212161
AHRI 214212161 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 235SAN024**AA* and indoor unit CAA**3721AM*.
AHRI 214212162
AHRI 214212162 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 246SAN024**AA* and indoor unit CAA**3721AM*.
AHRI 214212163
AHRI 214212163 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH5SAN524**AA* and indoor unit CAA**3721AM*.
Source-backed diagnostics
Error codes
45 codes matched to Bryant 926TC66100V21 through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.