Furnace
Bryant 926TC66120V24*D
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Model pattern
- Certifications
- 60 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 95 %
Matched systems
Certificates
59 verified catalog relationships.
AHRI 215625764
AHRI 215625764 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN048**AA* and indoor unit CVAVA6124XMA*.
AHRI 215625765
AHRI 215625765 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN548**AA* and indoor unit CVAVA6124XMA*.
AHRI 215625766
AHRI 215625766 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH8TAN548**AA* and indoor unit CVAVA6124XMA*.
AHRI 215629491
AHRI 215629491 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN060**AA* and indoor unit CAA**6024AM*.
AHRI 215629492
AHRI 215629492 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN560**AA* and indoor unit CAA**6024AM*.
AHRI 215629493
AHRI 215629493 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH8TAN560**AA* and indoor unit CAA**6024AM*.
AHRI 215630451
AHRI 215630451 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN060**AA* and indoor unit CAA**6124AM*.
AHRI 215630452
AHRI 215630452 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN560**AA* and indoor unit CAA**6124AM*.
Source-backed diagnostics
Error codes
45 codes matched to Bryant 926TC66120V24*D through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.