Evaporator coil

Back to Bryant products

Bryant Evaporator coil CSAH*3612AM*

Bryant Bryant AHRI Indoor - CSAHP cased horizontal slab evaporator coil Evaporator coil Repair, maintenance, and replacement planning
Bryant CSAH*3612AM* product image

Technical Specifications

Product Specs

  • AHRI unit role: Indoor
  • AHRI model/pattern: CSAH*3612AM*
  • AHRI records represented: 594
  • AHRI equipment type: Central HP
  • AHRI tonnage: 1.9
  • AHRI refrigerant: R-454B
  • Verified catalog model: CSAHP3612AMA
  • Verified product family: CSAHP cased horizontal slab evaporator coil
  • Verified catalog brand: Bryant
  • Verified AHRI-to-catalog mapping: CSAH*3612AM* -> CSAHP3612AMA
  • Product family: CSAHP cased horizontal slab evaporator coil
  • Nominal capacity: 3 ton
  • Nominal cooling capacity: 36,000 BTU nominal cooling capacity
  • Cabinet width: 12 in.
  • Refrigerant: R-454B
  • Metering: factory-installed refrigerant-specific TXV
  • Installation: horizontal cased slab coil
  • Catalog Model: CSAHP3612AMA
  • Manufacturer Number: CSAHP3612AMA
  • Catalog SKU: 1604089257757575
  • Catalog Brand: Carrier, Bryant, Payne
  • Product Family: CSAHP
  • Tonnage: 3
  • Refrigerant: R-454B
  • Air Flow Direction: Horizontal
  • Brand: Carrier, Bryant, Payne
  • CFM: 900-1,500
  • Cabinet Width: 12
  • Cased: YES
  • Coil Fin Material: Aluminum
  • Coil Pipe Material: Aluminum
  • Coil Shape Designation: Slab-Coil
  • Coil Type: Cased
  • Cooling Capacity: 36,000
  • Cooling Rated Capacity Btu/h: 36000
  • Corrosion Protected Coil: NO
  • Country Of Origin: MEX
  • Drain Connection Quantity: 2
  • Drain Connection Size: 3/4"
  • Height: 28.3
  • Length: 28.8
  • Liquid Line Fitting Type: Sweat or Braze
  • Liquid Line Size (OD): 3/8"
  • Metering Device: TXV/TEV - Thermostatic Expansion Valve
  • OPT Code: 1PCSAHP3612AMA
  • Prop 65: YES
  • Suction Line Fitting Type: Sweat or Braze
  • Suction Line Size (OD): 3/4"
  • UPC: See Optical
  • Weight: 60
  • Width: 12

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 216737997

AHRI 216737997 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 216738008

AHRI 216738008 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 216738017

AHRI 216738017 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 216738028

AHRI 216738028 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 216738038

AHRI 216738038 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 216738049

AHRI 216738049 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 216738058

AHRI 216738058 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 216738069

AHRI 216738069 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 216738079

AHRI 216738079 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 216738089

AHRI 216738089 identifies a Mass Save qualified Central HP <5.4 tons from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Loading more

Service planning

How GreenFlow handles CSAH*3612AM* requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers