Heat pump condensing unit

Back to Carrier products

Carrier Heat pump condensing unit 27VNA348A*030*

Carrier Carrier AHRI Outdoor - 27VNA3 Heat pump condensing unit Repair, maintenance, and replacement planning
Carrier 27VNA348A*030* product image

Technical Specifications

Product Specs

  • AHRI unit role: Outdoor
  • AHRI model/pattern: 27VNA348A*030*
  • AHRI records represented: 113
  • AHRI equipment type: Central HP
  • AHRI tonnage: 3.875
  • AHRI refrigerant: R-454B
  • Verified catalog model: 27VNA348A003
  • Verified product family: 27VNA3
  • Verified catalog brand: Carrier
  • Catalog Model: 27VNA348A003
  • Manufacturer Number: 27VNA348A003
  • Catalog SKU: 1604089257110133
  • Catalog Brand: Carrier
  • Product Family: 27VNA3
  • Tonnage: 4
  • SEER2: 23
  • Refrigerant: R-454B
  • Approvals: UL Listed
  • Brand: Carrier
  • CFM: 5,000
  • Color: Gray
  • Compressor Type: Rotary
  • Condenser Coil Fins Per Inch (FPI): 20
  • Condenser Fan Blade Diameter: 26
  • Condenser Fan CFM: 5000
  • Condenser Fan Discharge: Vertical
  • Condenser Fan Motor Qty: 1
  • Condenser Motor HP: 1/3
  • Condenser Motor RPM: 200-800
  • Condenser Motor Speeds: Variable
  • Condenser Motor Type: ECM (Electronically Commutated Motor)
  • Cooling Capacity: 48,000
  • Country Of Origin: USA
  • Cycle/Hertz: 60 Hz
  • EER2: 13
  • Energy Star Rated: YES
  • Full Load Amps: 0.88
  • HSPF2: 10
  • Heating Capacity: 48,000
  • Height: 47.19
  • Inverter: NO
  • Length: 35
  • Liquid Line Fitting Type: Sweat or Braze
  • Liquid Line Size (OD): 3/8"
  • Maximum Overcurrent Protection (MOCP): 40
  • Metering Device: EEV - Electronic Expansion Valve
  • OPT Code: 1P27VNA348A003
  • Phase: Single
  • Prop 65: YES
  • Rated Load Amps (RLA): 20.4
  • Sound Level (dBA): 56
  • Stages Cooling: Variable
  • Stages Heating: Variable
  • Suction Line Fitting Type: Sweat or Braze
  • Suction Line Size (OD): 1 1/8"
  • Tier: Infinity
  • UPC: See Optical
  • Voltage: 208-230 VAC
  • Weight: 334
  • Width: 35

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 215931486

AHRI 215931486 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit FE5BNBD60L*+UI.

Eligible Central HP <5.4 tons

AHRI 215933974

AHRI 215933974 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit CAA**4821AM*+UI.

Eligible Central HP <5.4 tons

AHRI 215933984

AHRI 215933984 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit CAA**4821AM*+UI.

Eligible Central HP <5.4 tons

AHRI 215933994

AHRI 215933994 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit CAA**4821AM*+UI.

Eligible Central HP <5.4 tons

AHRI 215934004

AHRI 215934004 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit CAA**4821AM*+UI.

Eligible Central HP <5.4 tons

AHRI 215934014

AHRI 215934014 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit CAA**4821AM*+UI.

Eligible Central HP <5.4 tons

AHRI 215934024

AHRI 215934024 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit CAA**4821AM*+UI.

Eligible Central HP <5.4 tons

AHRI 215934034

AHRI 215934034 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit CAA**4821AM*+UI.

Eligible Central HP <5.4 tons

AHRI 215934044

AHRI 215934044 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit CAA**4821AM*+UI.

Eligible Central HP <5.4 tons

AHRI 215934054

AHRI 215934054 identifies a Mass Save qualified Central HP <5.4 tons from CARRIER with outdoor unit 27VNA348A*030* and indoor unit CAA**4821AM*+UI.

Loading more

Service planning

How GreenFlow handles 27VNA348A*030* requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Additional Services

Brands We Service

Popular cities

Service Areas

Our Happy Customers