Air Conditioner

Back to Carrier products

Carrier Air Conditioner ® Gemini® - 15 Ton Commercial Air Cooled Condensing Unit R-410A (208/230-3-60)

Carrier Commercial Air Conditioner - 38AUZ Air Conditioner Repair, maintenance, and replacement planning
Carrier® Gemini® - 15 Ton Commercial Air Cooled Condensing Unit R-410A (208/230-3-60) product image

Technical Specifications

Product Specs

  • Model: 38AUZA16A0A5-0A0A0
  • Manufacturer Number: 38AUZA16A0A5-0A0A0
  • Vendor Number: 38AUZA16A0A5-0A0A0
  • Catalog Brand: Carrier®
  • Product Family: 38AUZ
  • AHRI Usage: Outdoor
  • Approvals: AHRI 340/360; ASHRAE 90.1; eETLus Listed; cULus Listed
  • Brand: Carrier®
  • CFM: 9,000
  • Color: Gray
  • Compressor Type: Scroll
  • Condenser Coil Fins Per Inch (FPI): 17
  • Condenser Fan Blade Diameter: 22
  • Condenser Fan CFM: 9000
  • Condenser Fan Discharge: Vertical
  • Condenser Fan Motor Qty: 3
  • Condenser Motor HP: 1/4
  • Condenser Motor RPM: 1,100
  • Condenser Motor Speeds: 1
  • Condenser Motor Type: PSC (Permanent Split Capacitor)
  • Cooling Capacity: 184,000
  • Cooling Rated Capacity Btu/h: 184000
  • Corrosion Protected Coil: NO
  • Country Of Origin: MEX
  • Cubic Measurement: 123.4566
  • Cycle/Hertz: 60 Hz
  • Dimensional Weight: 1535
  • EER: 11.2
  • Energy Star Rated: NO
  • Full Load Amps: 1.5
  • Height: 50.375
  • IEER: 13.2
  • Length: 45.125
  • Liquid Line Fitting Type: Sweat or Braze
  • Liquid Line Size (OD): 5/8"
  • Locked Rotor Amps (LRA): 164
  • Maximum Overcurrent Protection (MOCP): 80
  • OPT Code: 1P38AUZA16A0A5-0A0A0
  • Phase: Three
  • Prop 65: YES
  • Rated Load Amps (RLA): 25
  • Refrigerant: R-410A
  • Sound Level (dBA): 83
  • Stages Cooling: 1
  • Suction Line Fitting Type: Sweat or Braze
  • Suction Line Size (OD): 1 3/8"
  • Tier: Gemini®
  • Tonnage: 15
  • UOM: EA
  • UPC: See Optical
  • Voltage: 208-230 VAC
  • Weight: 731
  • Width: 86.375

Useful troubleshooting details

  • Confirm the exact model number, serial number, installed equipment type, and site voltage before service or replacement planning.
  • Match replacement equipment and accessories against current Carrier compatibility requirements, refrigerant type, capacity, airflow, and local code requirements.

Service planning

How GreenFlow handles Carrier® Gemini® - 15 Ton Commercial Air Cooled Condensing Unit R-410A (208/230-3-60) requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers