Product troubleshooting
Carrier 38MURAQ36AB3 troubleshooting and error codes
These codes are matched from manufacturer documentation to this model's series or control platform. Keep checks visible and safe; do not open electrical, refrigerant, gas, combustion, or sealed equipment compartments.
Source-backed code set
32 matched codes
| Code | Meaning | System area | Priority |
|---|---|---|---|
| EC 51 | Outdoor EEPROM malfunction | Outdoor control board | Urgent |
| EL 01 | Indoor / outdoor units communication error | Indoor-outdoor communication | Urgent |
| EL 16 | Communication malfunction between adapter board and outdoor main board | Control communication | Urgent |
| PC 00 | IPM module protection | Inverter module | Urgent |
| PC 02 | Compressor top temperature or IPM high temperature protection | Compressor / inverter module | Urgent |
| PC 06 | Compressor discharge temperature protection | Compressor discharge | Urgent |
| PC 08 | Outdoor overcurrent protection | Outdoor electrical protection | Urgent |
| PC 0A | High temperature protection of condenser | Condenser coil | Urgent |
| PC 0F | PFC module protection | Power-factor correction module | Urgent |
| PC 10 | Outdoor unit low AC voltage protection | Outdoor power supply | Urgent |
| PC 11 | Outdoor main control board DC bus high voltage protection | Outdoor main control board | Urgent |
| PC 12 | Outdoor main control board DC bus high voltage protection / 341 MCE error | Outdoor main control board | Urgent |
| PC 30 | High pressure protection | Refrigerant pressure | Urgent |
| PC 31 | Low pressure protection | Refrigerant pressure | Urgent |
| PC 40 | Communication malfunction between IPM board and outdoor main board | Inverter communication | Urgent |
| PC 41 | Outdoor compressor current sampling circuit failure | Compressor current sensing | Urgent |
| PC 43 | Outdoor compressor lack phase protection | Compressor phase protection | Urgent |
| PC 44 | Outdoor unit zero speed protection | Outdoor drive control | Urgent |
| PC 45 | Outdoor unit IR chip drive failure | Outdoor drive control | Urgent |
| PC 46 | Compressor speed out of control | Compressor drive | Urgent |
| PC 49 | Compressor overcurrent failure | Compressor electrical protection | Urgent |
| EC 52 | Condenser coil temperature sensor T3 open circuit or short circuit | Temperature sensor | Service |
| EC 53 | Outdoor room temperature sensor T4 open circuit or short circuit | Temperature sensor | Service |
| EC 54 | Compressor discharge temperature sensor TP open circuit or short circuit | Temperature sensor | Service |
| EC 57 | Refrigerant pipe temperature sensor error | Temperature sensor | Service |
| EC 5C | High pressure sensor open circuit or short circuit | Pressure sensor | Urgent |
| EC 71 | Outdoor DC fan motor overcurrent failure | Outdoor fan motor | Urgent |
| EC 72 | Outdoor DC fan motor lack phase failure | Outdoor fan motor | Urgent |
| EC 73 | Outdoor DC fan motor zero-speed failure | Outdoor fan motor | Urgent |
| EC 07 | Outdoor fan speed out of control | Outdoor fan motor | Urgent |
| PC 0L | Low ambient temperature protection | Outdoor operating conditions | Service |
| LC 06 | High temperature protection of IPM module | Inverter module | Urgent |
No matching error codes found.