Heat Pump

Back to Carrier products

Carrier Heat Pump 2 Ton Heat Pump Crossover System Fan Coil Unit R-454B (208/230-1)

Carrier Residential Heat Pump - 45MUAA Heat Pump Repair, maintenance, and replacement planning
Carrier 2 Ton Heat Pump Crossover System Fan Coil Unit R-454B (208/230-1) product image

Technical Specifications

Product Specs

  • Model: 45MUAAQ24XX3
  • Manufacturer Number: 45MUAAQ24XX3
  • Vendor Number: 45MUAAQ24XX3
  • Catalog Brand: Carrier®, Bryant®
  • Product Family: 45MUAA
  • AHRI Usage: Indoor AHU
  • Air Flow Direction: Multi-Position
  • Approvals: ETL Listed; UL Listed
  • Blower Motor HP: 1/3
  • Blower Motor RPM: 550
  • Blower Motor Speeds: 3
  • Blower Motor Type: ECM (Electronically Commutated Motor)
  • Brand: Carrier®, Bryant®
  • CFM: 629.8-824.04
  • Cabinet Width: 21
  • Color: Gray
  • Cooling Capacity: 24,000
  • Cooling Rated Capacity Btu/h: 24000
  • Country Of Origin: CHN
  • Cycle/Hertz: 60 Hz
  • Drain Connection Size: 3/4"
  • Electric Heat Range [kW]: 5-15
  • Energy Star Rated: YES
  • Evaporator Coil Fins Per Inch (FPI): 20
  • Filter Size: 16" x 20" x 1
  • Heating Capacity: 7,100-30,000
  • Height: 45
  • Includes Filter Rack: YES
  • Length: 21.02
  • Liquid Line Fitting Type: Flare
  • Liquid Line Size (OD): 3/8"
  • Maximum Overcurrent Protection (MOCP): 15
  • Metering Device: EEV - Electronic Expansion Valve
  • Mounting Type: Ducted Multi-Position
  • OPT Code: 1P45MUAAQ24XX3
  • Phase: Single
  • Prop 65: YES
  • Refrigerant: R-454B
  • Suction Line Fitting Type: Flare
  • Suction Line Size (OD): 3/4"
  • Tier: Standard
  • Tonnage: 2
  • UPC: See Optical
  • Voltage: 115 VAC; 208-230 VAC
  • Weight: 105.6
  • Width: 17.52

Useful troubleshooting details

  • Confirm the exact model number, serial number, installed equipment type, and site voltage before service or replacement planning.
  • Match replacement equipment and accessories against current Carrier compatibility requirements, refrigerant type, capacity, airflow, and local code requirements.

Service planning

How GreenFlow handles 2 Ton Heat Pump Crossover System Fan Coil Unit R-454B (208/230-1) requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.