Product troubleshooting

Back to Carrier® WeatherMaker® - 10 Ton Packaged Rooftop Gas Heat & Electric Cool Unit R-410A (208/230-3)

Carrier® WeatherMaker® - 10 Ton Packaged Rooftop Gas Heat & Electric Cool Unit R-410A (208/230-3) troubleshooting and error codes

Use this table to identify what the visible code may mean and what information to share when scheduling service. Keep checks simple and visible; do not open electrical, refrigerant, gas, or sealed equipment compartments.

Error-code table

Search codes for Carrier® WeatherMaker® - 10 Ton Packaged Rooftop Gas Heat & Electric Cool Unit R-410A (208/230-3)

Code Meaning System area Safe first step Action
Off Hardware failure IGC board Record the displayed code or LED pattern, avoid repeated reset attempts, and schedule GreenFlow service. View details
1 Flash Fan ON delay modified Fan timing Record the displayed code or LED pattern, confirm thermostat or controller demand, check visible airflow and outdoor-area conditions, and schedule service if the condition remains. View details
3 Flashes Flame sense fault Flame sensing Record the displayed code or LED pattern, avoid repeated reset attempts, and schedule GreenFlow service. View details
4 Flashes Four consecutive limit switch fault Limit switch Record the displayed code or LED pattern, avoid repeated reset attempts, and schedule GreenFlow service. View details
5 Flashes Ignition fault Ignition Record the displayed code or LED pattern, avoid repeated reset attempts, and schedule GreenFlow service. View details
6 Flashes Induced draft motor fault Induced draft motor Record the displayed code or LED pattern, avoid repeated reset attempts, and schedule GreenFlow service. View details
7 Flashes Rollout switch lockout Rollout switch Record the displayed code or LED pattern, avoid repeated reset attempts, and schedule GreenFlow service. View details
8 Flashes Internal control lockout IGC board Record the displayed code or LED pattern, avoid repeated reset attempts, and schedule GreenFlow service. View details
9 Flashes Temporary software lockout IGC board Record the displayed code or LED pattern, avoid repeated reset attempts, and schedule GreenFlow service. View details

Safety note

What is safe to check before service

These pages are meant to help document the issue, not replace diagnosis. GreenFlow should handle pressure-switch, electrical, refrigerant, lockout, recurring, and warranty-related conditions.

Safe visible checks

  • Thermostat display and settings
  • Filter condition and return-air path
  • Visible outdoor-unit obstruction
  • Photos of the code, unit, and nameplate

Stop and call

  • Repeated lockouts or recurring faults
  • Pressure-switch or sensor faults
  • Electrical odor, unusual noise, or ice buildup
  • Any sealed cabinet, refrigerant, gas, or warranty issue