Rooftop Unit

Back to Carrier products

Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) service and support

Carrier Commercial Rooftop Unit - 50FC Rooftop Unit Repair, maintenance, and replacement planning
Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) product image

Product service snapshot

Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) service details

Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) is a Carrier® rooftop unit record from the Carrier Enterprise catalog. Catalog model: 50FC-M09A2A1-6B0A0. Product family: 50FC. Green Flow Solution uses this page for commercial model identification, service planning, maintenance conversations, repair diagnostics, and replacement matching.

  • Brand: Carrier
  • Model or series: Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60)
  • Equipment type: Rooftop Unit
  • Product group: Commercial Rooftop Unit - 50FC

Technical snapshot

Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) technical snapshot

Product Specs

  • Model: 50FC-M09A2A1-6B0A0
  • Manufacturer Number: 50FC-M09A2A1-6B0A0
  • Vendor Number: 50FC-M09A2A1-6B0A0
  • Catalog Brand: Carrier®
  • Product Family: 50FC
  • AHRI Usage: Packaged
  • Air Flow Direction: Horizontal / Vertical
  • Approvals: ETL Listed; UL Listed
  • Blower Motor HP: 2 2/5 BHP
  • Blower Motor RPM: 250-2,000
  • Blower Motor Speeds: Variable
  • Blower Motor Type: ECM (Electronically Commutated Motor)
  • Blower Wheel Diameter: 22"
  • Brand: Carrier®
  • CFM: 1,275-4,250
  • Color: Gray
  • Compressor Type: Scroll
  • Condenser Coil Fins Per Inch (FPI): 18
  • Condenser Fan Blade Diameter: 22
  • Condenser Fan CFM: 3400
  • Condenser Fan Motor Qty: 2
  • Condenser Motor HP: 1/4
  • Condenser Motor RPM: 1,100
  • Condenser Motor Speeds: 1
  • Condenser Motor Type: PSC (Permanent Split Capacitor)
  • Cooling Capacity: 98,000
  • Country Of Origin: Varies
  • Cubic Measurement: 111.4688
  • Cycle/Hertz: 60 Hz
  • Drain Connection Size: 3/4"
  • Drive Type: Direct
  • EER: 11.4
  • Energy Star Rated: NO
  • Evaporator Coil Fins Per Inch (FPI): 15
  • Evaporator Coil Metering Device: TXV/TEV - Thermostatic Expansion Valve
  • Height: 49.375
  • IEER: 15.2
  • Length: 59.5
  • Locked Rotor Amps (LRA): 41
  • Maximum Overcurrent Protection (MOCP): 20
  • OPT Code: 1P50FC-M09A2A1-6B0A0
  • Outdoor Air Filter Size (OA) In Inches (W X H X D): 20 x 24 x 1
  • Phase: Three
  • Prop 65: YES
  • Rated Load Amps (RLA): 4.8
  • Refrigerant: R-410A
  • Return Air Filter Size (RA) In Inches (W X H X D): (4) 16 x 16 x 2
  • Sound Level (dBA): 79
  • Stages Cooling: 2
  • Tier: WeatherMaker®
  • Tonnage: 8.5
  • UPC: See Optical
  • Voltage: 575 VAC
  • Weight: 967
  • Width: 88.125

Useful troubleshooting details

  • Confirm the exact model number, serial number, installed equipment type, and site voltage before service or replacement planning.
  • Match replacement equipment and accessories against current Carrier compatibility requirements, refrigerant type, capacity, airflow, and local code requirements.

Service planning

How GreenFlow handles Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) service questions

What Carrier Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) alarm or error-code details should I share?

Share the exact alarm, fault, or status message shown on the unit controller, thermostat, service app, or building automation system. Photos of the control screen, unit nameplate, and thermostat/BAS screen help the team understand the issue before dispatch.

What should I check before requesting Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) service?

Confirm the thermostat or building schedule, whether one tenant space or multiple zones are affected, recent filter or maintenance history, and whether the RTU is locked out, noisy, short cycling, or not responding. Do not open rooftop panels or reset electrical equipment if it is unsafe.

Why would a Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) run but not heat or cool correctly?

Possible causes include airflow restrictions, dirty filters, economizer or damper issues, sensor or control faults, compressor or reversing-valve issues, defrost problems, refrigerant concerns, electrical faults, or building automation scheduling. A technician needs the full symptom and alarm context to diagnose it safely.

When is a Carrier® WeatherMaker® - 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit (575-3-60) issue urgent?

Treat the request as urgent when no heat or no cooling affects occupied space, an alarm or lockout is active, there is electrical odor, unusual noise, water intrusion, unsafe rooftop access, or repeated tenant comfort complaints. Include business hours and access notes when scheduling.

Popular cities

Service Areas

Our Happy Customers