Furnace
Day & Night N96MSN1002120A**D
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Model pattern
- Certifications
- 34 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 95 %
Matched systems
Certificates
33 verified catalog relationships.
AHRI 214161273
AHRI 214161273 identifies a HP - Split System from Day & Night with outdoor unit C5H6S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 214211896
AHRI 214211896 identifies a HP - Split System from Day & Night with outdoor unit N5H5S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 214211897
AHRI 214211897 identifies a HP - Split System from Day & Night with outdoor unit R5H5S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 216677348
AHRI 216677348 identifies a Mass Save qualified HP - Split System from Day & Night with outdoor unit D5CURAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216735846
AHRI 216735846 identifies a Mass Save qualified HP - Split System from Day & Night with outdoor unit D5CUHAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216737586
AHRI 216737586 identifies a Mass Save qualified HP - Split System from Day & Night with outdoor unit D5CUHAH24AAK and indoor unit ESH5X30M12A*.
AHRI 216738586
AHRI 216738586 identifies a Mass Save qualified HP - Split System from Day & Night with outdoor unit D5CUHAH24AAK and indoor unit ESH5X36M12A*.
AHRI 217395124
AHRI 217395124 identifies a Mass Save qualified HP - Split System from Day & Night with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit ESH5X42M12A*.
Source-backed diagnostics
Error codes
32 codes matched to Day & Night N96MSN1002120A**D through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout - after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.