Furnace
Heil N96MSN0401410A
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Exact model
- Certifications
- 17 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 96 %
Matched systems
Certificates
16 verified catalog relationships.
AHRI 216733427
AHRI 216733427 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK and indoor unit EA*5X25M17A*.
AHRI 216735172
AHRI 216735172 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK and indoor unit EA*5X37M17A*.
AHRI 217632886
AHRI 217632886 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X24M14A*.
AHRI 217633030
AHRI 217633030 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X24M17A*.
AHRI 217633210
AHRI 217633210 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X25M17A*.
AHRI 217633317
AHRI 217633317 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X30M14A*.
AHRI 217633461
AHRI 217633461 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X30M17A*.
AHRI 217633641
AHRI 217633641 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X36M17A*.
Source-backed diagnostics
Error codes
32 codes matched to Heil N96MSN0401410A through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout - after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.