Furnace
Heil N96MSN0401410A**D
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Model pattern
- Certifications
- 17 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 95 %
Matched systems
Certificates
16 verified catalog relationships.
AHRI 216733427
AHRI 216733427 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK and indoor unit EA*5X25M17A*.
AHRI 216735172
AHRI 216735172 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK and indoor unit EA*5X37M17A*.
AHRI 217632886
AHRI 217632886 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X24M14A*.
AHRI 217633030
AHRI 217633030 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X24M17A*.
AHRI 217633210
AHRI 217633210 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X25M17A*.
AHRI 217633317
AHRI 217633317 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X30M14A*.
AHRI 217633461
AHRI 217633461 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X30M17A*.
AHRI 217633641
AHRI 217633641 identifies a Mass Save qualified HP - Split System from Heil with outdoor unit D5CUHAH24AAK+TIC2025-0016 and indoor unit EA*5X36M17A*.
Source-backed diagnostics
Error codes
32 codes matched to Heil N96MSN0401410A**D through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout - after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.