Product troubleshooting

Back to Keeprite N96MSN0401410A

Keeprite N96MSN0401410A troubleshooting and error codes

These codes are matched from manufacturer documentation to this model's series or control platform. Keep checks visible and safe; do not open electrical, refrigerant, gas, combustion, or sealed equipment compartments.

Source-backed code set

32 matched codes

CodeMeaningSystem areaPriority
10.1L1 polarity faultLine power / polarityUrgent
12.1W on at power upThermostat input / startupService
13.1Limit lockout - switch open longer than 3 minutes in Main Limit circuitMain limit circuitUrgent
14.1Ignition lockout - after 4 consecutive ignition triesIgnition / flame provingUrgent
14.2Flame lost 3 times after 70s of heatingFlame sensingUrgent
14.3Lockout - 7 loss of flame events during a heat requestFlame sensingUrgent
21.124VAC sensed on gas valve when it should not beGas valve circuitUrgent
22.1False flameFlame sensingUrgent
23.1Stuck closed Main pressure switchMain pressure switchUrgent
23.2Stuck closed secondary pressure switchSecondary pressure switchUrgent
24.1Fuse faultLow-voltage control circuitUrgent
25.1No program info in micro, no heating operationFurnace control programmingUrgent
25.2Corrupted program file, reprogram control using service app or super plugFurnace control programmingUrgent
25.3Twinned units are not identical; program numbers do not matchTwinning / control programmingUrgent
25.4Main program invalid, using backup program to operateFurnace control programmingService
25.5Installer settings corruptedFurnace control settingsService
25.6Wrong program for control usedFurnace control programmingUrgent
25.7Non-condensing program detected in a condensing modelFurnace control programmingUrgent
27.1Program in super plug is missingControl programming accessoryUrgent
27.2Program in super plug is not recognized or corruptedControl programming accessoryUrgent
27.3Super plug programming failedControl programming accessoryUrgent
31.2Open secondary pressure switch (HPS)Secondary pressure switchUrgent
31.3Secondary pressure switch lockout - failed to close after three trialsSecondary pressure switchUrgent
32.1Open Main pressure switch (LPS)Main pressure switchUrgent
33.1A switch has opened in the Main Limit circuitMain limit circuitUrgent
34.1Ignition fault - during four consecutive ignition trialsIgnition / flame provingUrgent
34.2Flame loss before heating blower on delayFlame sensingUrgent
34.3Flame loss after heating blower on delayFlame sensingUrgent
45.1Control failure - flame circuit fault, memory mismatch or sequence errorFurnace control boardUrgent
45.2Control failure - gas valve relay will not closeFurnace control board / gas valve relayUrgent
45.3Control failure - EEPROM memory issueFurnace control boardUrgent
46.1Momentary loss of powerElectrical supplyNotice