Furnace
Keeprite N96MSN0802120A
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Exact model
- Certifications
- 26 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 97 %
Matched systems
Certificates
25 verified catalog relationships.
AHRI 216677313
AHRI 216677313 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CURAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216735836
AHRI 216735836 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216737576
AHRI 216737576 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH24AAK and indoor unit ESH5X30M12A*.
AHRI 216738576
AHRI 216738576 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH24AAK and indoor unit ESH5X36M12A*.
AHRI 217396632
AHRI 217396632 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit EA*5X43M21A*.
AHRI 217397060
AHRI 217397060 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit EA*5X42M21A*.
AHRI 217397488
AHRI 217397488 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit EA*5X37M21A*.
AHRI 217488103
AHRI 217488103 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH36AAK+TIC2025-0016 and indoor unit EA*5X37M21A*.
Source-backed diagnostics
Error codes
32 codes matched to Keeprite N96MSN0802120A through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout - after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.