Furnace
Keeprite N96MSN1002120A
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Exact model
- Certifications
- 34 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 96.3 %
Matched systems
Certificates
33 verified catalog relationships.
AHRI 214161274
AHRI 214161274 identifies a HP - Split System from Keeprite with outdoor unit C5H6S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 214211898
AHRI 214211898 identifies a HP - Split System from Keeprite with outdoor unit N5H5S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 214211899
AHRI 214211899 identifies a HP - Split System from Keeprite with outdoor unit R5H5S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 216677349
AHRI 216677349 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CURAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216735847
AHRI 216735847 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216737587
AHRI 216737587 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH24AAK and indoor unit ESH5X30M12A*.
AHRI 216738587
AHRI 216738587 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH24AAK and indoor unit ESH5X36M12A*.
AHRI 217395125
AHRI 217395125 identifies a Mass Save qualified HP - Split System from Keeprite with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit ESH5X42M12A*.
Source-backed diagnostics
Error codes
32 codes matched to Keeprite N96MSN1002120A through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout - after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.