Evaporator coil

Back to Kenmore products

Kenmore Evaporator coil EVM5X60M24A*

Kenmore Kenmore AHRI Indoor - EVM5X multipoise cased V evaporator coil Evaporator coil Repair, maintenance, and replacement planning
Kenmore EVM5X60M24A* product image

Technical Specifications

Product Specs

  • AHRI unit role: Indoor
  • AHRI model/pattern: EVM5X60M24A*+WALLCON
  • AHRI records represented: 113
  • AHRI equipment type: Central HP
  • AHRI tonnage: 4
  • AHRI refrigerant: R-454B
  • Verified catalog model: EVM5X60M24A*+WALLCON
  • Verified product family: EVM5X multipoise cased V evaporator coil
  • Verified catalog brand: Kenmore
  • Verified ENERGY STAR dataset: ENERGY STAR Certified Heat Pumps
  • ENERGY STAR partner: Carrier Corporation
  • ENERGY STAR outdoor brand: Kenmore
  • ENERGY STAR series: Deluxe 20 VS Heat Pump
  • ENERGY STAR outdoor model: (C,H,T)5H0V48*K*AAA*
  • ENERGY STAR indoor model: EVM5X60M24A*+WALLCON
  • ENERGY STAR furnace model: *80CSU0802120A*
  • Matched-system SEER2: 19.00
  • Matched-system EER2: 10.00
  • Matched-system HSPF2: 9.00
  • Matched-system cooling capacity: 48,000 BTU/h
  • Matched-system heating capacity at 47F: 50,000 BTU/h
  • Matched-system heating capacity at 17F: 46,000 BTU/h
  • Compressor staging: Continuously variable
  • Refrigerant: R-454B (GWP:470 | Lower GWP)
  • ENERGY STAR certified date: 2026-05-01
  • ENERGY STAR source dataset: https://data.energystar.gov/d/83eb-xbyy
  • Carrier-family public product page: https://www.airquestcomfort.com/en/us/products/evaporator-coils/evm5x
  • Verified Carrier-family model family: EVM5X
  • AHRI indoor model/pattern: EVM5X60M24A*+WALLCON
  • Nominal capacity: 5 ton
  • Nominal cooling capacity: 60,000 BTU nominal cooling capacity
  • Cabinet width: 24 in.
  • Configuration: multipoise cased V coil
  • Application: matched indoor evaporator coil for air conditioner or heat pump systems

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 215675851

AHRI 215675851 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215675861

AHRI 215675861 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215675871

AHRI 215675871 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215675881

AHRI 215675881 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215675891

AHRI 215675891 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215675901

AHRI 215675901 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215675911

AHRI 215675911 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215675921

AHRI 215675921 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215675931

AHRI 215675931 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215675941

AHRI 215675941 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EVM5X60M24A*+WALLCON.

Loading more

Service planning

How GreenFlow handles EVM5X60M24A* requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers