Technical Specifications

Product Specs

  • AHRI unit role: Furnace
  • AHRI model/pattern: *80CTL0901716B*
  • AHRI records represented: 170
  • AHRI equipment type: Central HP
  • AHRI tonnage: 1.9
  • AHRI refrigerant: R-454B
  • Verified catalog model: *80CTL0901716B*
  • Verified product family: Ion 80 Variable-Speed Gas Furnace
  • Verified catalog brand: Kenmore
  • Verified ENERGY STAR dataset: ENERGY STAR Certified Heat Pumps
  • ENERGY STAR partner: Carrier Corporation
  • ENERGY STAR outdoor brand: Kenmore
  • ENERGY STAR series: Deluxe 20 VS Heat Pump
  • ENERGY STAR outdoor model: (C,H,T)5H0V24*K*AAA*
  • ENERGY STAR indoor model: EA*5X24M17A*+WALLCON
  • ENERGY STAR furnace model: *80CTL0901716B*
  • Matched-system SEER2: 17.00
  • Matched-system EER2: 10.00
  • Matched-system HSPF2: 9.00
  • Matched-system cooling capacity: 22,800 BTU/h
  • Matched-system heating capacity at 47F: 24,000 BTU/h
  • Matched-system heating capacity at 17F: 20,400 BTU/h
  • Compressor staging: Continuously variable
  • Refrigerant: R-454B (GWP:470 | Lower GWP)
  • ENERGY STAR certified date: 2025-02-17
  • ENERGY STAR source dataset: https://data.energystar.gov/d/83eb-xbyy
  • Carrier-family public product page: https://www.airquestcomfort.com/en/us/products/gas-furnaces/ion-80-variable-speed-gas-furnace
  • Verified Carrier-family model family: F80CTL
  • AHRI furnace model/pattern: *80CTL0901716B*
  • Nominal input: 90,000 BTU/h input
  • AFUE family: 80%
  • Heating stages: two-stage
  • Blower: variable-speed
  • NOx classification: standard
  • Cabinet width code: 17
  • Application: matched gas furnace for split-system air conditioner or heat pump combinations

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 215667066

AHRI 215667066 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V24*K*AAA* and indoor unit EA*5X24M17A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215667230

AHRI 215667230 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V24*K*AAA* and indoor unit EA*5X25M17A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215667462

AHRI 215667462 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V24*K*AAA* and indoor unit EA*5X30M17A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215667659

AHRI 215667659 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V24*K*AAA* and indoor unit EA*5X36M17A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215667770

AHRI 215667770 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V24*K*AAA* and indoor unit EA*5X37M17A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215667858

AHRI 215667858 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V24*K*AAA* and indoor unit EA*5X37M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215668578

AHRI 215668578 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit EA*5X37M17A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215668682

AHRI 215668682 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit EA*5X37M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215668842

AHRI 215668842 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit EA*5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215669002

AHRI 215669002 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit EA*5X43M21A*+WALLCON.

Loading more

Service planning

How GreenFlow handles *80CTL0901716B* requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service