Heat pump condensing unit

Back to Kenmore products

Kenmore Heat pump condensing unit B5H0V60*K*AAA*

Kenmore Kenmore AHRI Outdoor - Ion 20 Variable-Speed Heat Pump Heat pump condensing unit Repair, maintenance, and replacement planning
Kenmore B5H0V60*K*AAA* product image

Technical Specifications

Product Specs

  • AHRI unit role: Outdoor
  • AHRI model/pattern: B5H0V60*K*AAA*
  • AHRI records represented: 154
  • AHRI equipment type: Central HP
  • AHRI tonnage: 4.791666666666667
  • AHRI refrigerant: R-454B
  • Verified catalog model: B5H0V60*K*AAA*
  • Verified product family: Ion 20 Variable-Speed Heat Pump
  • Verified catalog brand: Kenmore
  • Verified ENERGY STAR dataset: ENERGY STAR Certified Heat Pumps
  • ENERGY STAR partner: Carrier Corporation
  • ENERGY STAR outdoor brand: Kenmore
  • ENERGY STAR series: Deluxe 20 VS Heat Pump
  • ENERGY STAR outdoor model: B5H0V60*K*AAA*
  • ENERGY STAR indoor model: EVM5X60M21A*+WALLCON
  • ENERGY STAR furnace model: *80CTL0702120B*
  • Matched-system SEER2: 18.00
  • Matched-system EER2: 9.00
  • Matched-system HSPF2: 9.00
  • Matched-system cooling capacity: 56,500 BTU/h
  • Matched-system heating capacity at 47F: 64,000 BTU/h
  • Matched-system heating capacity at 17F: 56,500 BTU/h
  • Compressor staging: Continuously variable
  • Refrigerant: R-454B (GWP:470 | Lower GWP)
  • ENERGY STAR certified date: 2026-05-01
  • ENERGY STAR source dataset: https://data.energystar.gov/d/83eb-xbyy
  • Carrier-family public product page: https://www.airquestcomfort.com/en/us/products/heat-pumps/ion-20-variable-speed-heat-pump-b5h0v
  • Verified Carrier-family model family: B5H0V
  • AHRI model/pattern: B5H0V60*K*AAA*
  • Nominal capacity: 5 ton
  • Nominal cooling capacity: 60,000 BTU nominal cooling capacity
  • Compressor: variable-speed
  • Sound level: as low as 54 dBA

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 218169422

AHRI 218169422 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit FCMA5B60L0D*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218169423

AHRI 218169423 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit EVM5X60M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218169424

AHRI 218169424 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit EVM5X60M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218169425

AHRI 218169425 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit EVM5X60M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218169426

AHRI 218169426 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit EVM5X60M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218169427

AHRI 218169427 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit EVM5X60M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218169428

AHRI 218169428 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit EVM5X60M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218169429

AHRI 218169429 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit EVM5X60M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218169430

AHRI 218169430 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit EVM5X60M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218169431

AHRI 218169431 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H0V60*K*AAA* and indoor unit EVM5X60M21A*+WALLCON.

Loading more

Service planning

How GreenFlow handles B5H0V60*K*AAA* requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers