Furnace
Lennox SLP99UH135XV60D*
- Category
- Furnace
- Series
- SLP99V Variable-Capacity Gas Furnace Series
- Model record
- Model pattern
- Certifications
- 18 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 98.4 %
Matched systems
Certificates
17 verified catalog relationships.
AHRI 210051203
AHRI 210051203 identifies a HP - Split System from Lennox with outdoor unit ML17XP1-048-230A** and indoor unit CHX35-60D-**-*+TDR.
AHRI 211465322
AHRI 211465322 identifies a HP - Split System from Lennox with outdoor unit EL22XPV-060-230A** and indoor unit CX35-60D+TDR.
AHRI 214624545
AHRI 214624545 identifies a HP - Split System from Lennox with outdoor unit ML17XP1-048-230A** and indoor unit CK40HT-60D-0*+TDR.
AHRI 214635534
AHRI 214635534 identifies a HP - Split System from Lennox with outdoor unit EL22XPV-060-230A** and indoor unit CK40CT-60D-0*+TDR.
AHRI 216776145
AHRI 216776145 identifies a HP - Split System from Lennox with outdoor unit SL22KLV-060-230A** and indoor unit CK40[C,U]T-60D-**+TDR.
AHRI 217117009
AHRI 217117009 identifies a HP - Split System from Lennox with outdoor unit EL21KLV-060-230A** and indoor unit CK40HT-60D-**+TDR.
AHRI 217117077
AHRI 217117077 identifies a HP - Split System from Lennox with outdoor unit EL21KLV-048-230A** and indoor unit CK40HT-60D-**+TDR.
AHRI 217117104
AHRI 217117104 identifies a HP - Split System from Lennox with outdoor unit EL21KLV-048-230A** and indoor unit CK40[C,U]T-60D-**+TDR.
Source-backed diagnostics
Error codes
56 codes matched to Lennox SLP99UH135XV60D* through its documented series or control platform.
Device communication problem; no other devices on the bus
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Low line voltage
Record the code, check the thermostat and filter, and schedule service if the condition remains.
High line voltage
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Line-voltage frequency out of range
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Low 24-volt control voltage
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Unresponsive device
Record the code, check the thermostat and filter, and schedule service if the condition remains.