Product troubleshooting

Back to Mitsubishi Electric MUZ-FS12NAH***

Mitsubishi Electric MUZ-FS12NAH*** troubleshooting and error codes

These codes are matched from manufacturer documentation to this model's series or control platform. Keep checks visible and safe; do not open electrical, refrigerant, gas, combustion, or sealed equipment compartments.

Source-backed code set

15 matched codes

CodeMeaningSystem areaPriority
1 blinkOutdoor power-system abnormalityOutdoor powerUrgent
2 blinksOutdoor thermistor short or open circuitOutdoor sensorsService
3 blinksOutdoor control-system nonvolatile-memory failureOutdoor controlService
6 blinksIndoor-outdoor serial-signal failureCommunicationService
11 blinksStop valve or closed-valve conditionRefrigerant circuitUrgent
16 blinksFour-way valve or pipe-temperature abnormalityReversing valveUrgent
17 blinksOutdoor refrigerant-system abnormalityRefrigerant circuitUrgent
2 blinks / restartOvercurrent protectionCompressor powerUrgent
3 blinks / restartDischarge-temperature overheat protectionCompressor dischargeUrgent
4 blinks / restartFin or control-board temperature overheat protectionOutdoor controlUrgent
5 blinks / restartHigh-pressure protectionRefrigerant pressureUrgent
8 blinks / restartCompressor synchronous abnormalityCompressorUrgent
10 blinks / restartOutdoor fan motor failureOutdoor fanService
12 blinks / restartCompressor phase-current detection failureCompressor powerUrgent
13 blinks / restartInverter DC bus-bar voltage detection failureInverter powerUrgent