34 matched codes

CodeMeaningSystem areaPriority
E001Heat exchanger overheatEquipment controlUrgent
E003Ignition failureCombustion / ventingUrgent
E004False flame detectionCombustion / ventingUrgent
E012Flame lossCombustion / ventingUrgent
E016Heat exchanger overheatEquipment controlUrgent
E030Exhaust overheatCombustion / ventingUrgent
E031Burner overheatCombustion / ventingUrgent
E046Abnormal operation: heat exchanger limit or thermistorTemperature / sensorService
E047Exhaust thermostat or thermistor open/shortCombustion / ventingUrgent
E060Abnormal operation: dual venturiCombustion / ventingUrgent
E109Abnormal operation: fan motorAirflow / fanService
E110Abnormal air pressure or exhaust blockageCombustion / ventingUrgent
E127Abnormal operation: air pressure sensor or air volume controlCombustion / ventingUrgent
E205Heating supply temperature sensorTemperature / sensorService
E218Heating return temperature sensorTemperature / sensorService
E278External supply sensor not detectedTemperature / sensorService
E279External return sensor not detectedTemperature / sensorService
E291Return temperature exceeds supply temperatureTemperature / sensorService
E302Low water pressureWater flow / hydronicsUrgent
E352High water pressureWater flow / hydronicsUrgent
E353Water pressure sensor issueTemperature / sensorUrgent
E480Domestic hot water tank temperature sensor not detectedTemperature / sensorService
E515Abnormal operation: PCBControls / communicationUrgent
E517Abnormal operation: DIP switch settingControls / communicationService
E594Abnormal operation: EEPROMControls / communicationUrgent
E615Abnormal operation: input and memoryControls / communicationService
E736Abnormal operation: cascade communicationControls / communicationService
E740Abnormal operation: outdoor temperature sensorTemperature / sensorService
E765Abnormal external pump operationWater flow / hydronicsService
E774Manual reset limitEquipment controlService
E775Auto reset limitEquipment controlService
E777Low water cutoff activatedWater flow / hydronicsService
E782Abnormal operation: front/main panel communicationControls / communicationService
E784Abnormal operation: zone controller communicationControls / communicationService