Product troubleshooting

Back to Navien NPF700-100H5CH

Navien NPF700-100H5CH troubleshooting and error codes

These codes are matched from manufacturer documentation to this model's series or control platform. Keep checks visible and safe; do not open electrical, refrigerant, gas, combustion, or sealed equipment compartments.

Source-backed code set

36 matched codes

CodeMeaningSystem areaPriority
E003Ignition failureCombustion / ventingUrgent
E004False flameCombustion / ventingUrgent
E012Flame loss during operationCombustion / ventingUrgent
E016Heat exchanger overheatEquipment controlUrgent
E030Abnormal exhaust temperatureCombustion / ventingUrgent
E031Burner overheatCombustion / ventingUrgent
E046Heat exchanger overheating sensor issueTemperature / sensorUrgent
E047Exhaust thermostat issueCombustion / ventingUrgent
E109Abnormal inducer fan motor operationAirflow / fanService
E205Heating supply temperature sensorTemperature / sensorService
E218Heating return temperature sensorTemperature / sensorService
E238Abnormal condensate or water-flow conditionWater flow / hydronicsService
E302Low water levelWater flow / hydronicsService
E311Abnormal water levelWater flow / hydronicsService
E351Abnormal water fillWater flow / hydronicsService
E360Abnormal cover switchEquipment controlService
E515Abnormal operation: PCBControls / communicationUrgent
E517Abnormal operation: DIP switch settingControls / communicationService
E593Abnormal operation: front panel keyControls / communicationService
E594Abnormal operation: EEPROMControls / communicationUrgent
E615Abnormal operation: input and memoryControls / communicationService
E740Abnormal operation: outdoor temperature sensorTemperature / sensorService
E762Improper vent pipe insertionCombustion / ventingUrgent
E774Manual reset limitEquipment controlService
E775Auto reset limitEquipment controlService
E782Abnormal operation: front/main panel communicationControls / communicationService
E786Improper front panel or panel connectionControls / communicationService
E788Abnormal gas type settingCombustion / ventingUrgent
E799Abnormal appliance control operationEquipment controlService
E805Inverter or control protectionRefrigerant / inverterUrgent
E810Inverter or compressor protectionRefrigerant / inverterUrgent
E811Inverter or compressor protectionRefrigerant / inverterUrgent
E818Voltage or inverter protectionRefrigerant / inverterUrgent
E822Discharge or inverter protectionTemperature / sensorUrgent
E860Abnormal water or system control operationWater flow / hydronicsService
E890Abnormal circulator operationWater flow / hydronicsService