Gas furnace

Back to Payne products

Payne Gas furnace PG97VTAA48080B**

Payne Payne AHRI Furnace - PG97VTA Gas furnace Repair, maintenance, and replacement planning
Payne PG97VTAA48080B** product image

Technical Specifications

Product Specs

  • AHRI unit role: Furnace
  • AHRI model/pattern: PG97VTAA48080B**
  • AHRI records represented: 92
  • AHRI equipment type: Central HP
  • AHRI tonnage: 1.9333333333333333
  • AHRI refrigerant: R-454B
  • Verified catalog model: PG97VTAA48080B
  • Verified product family: PG97VTA
  • Verified catalog brand: Bryant, Payne
  • Catalog Model: PG97VTAA48080B
  • Manufacturer Number: PG97VTAA48080B
  • Catalog SKU: 1604089265831730
  • Catalog Brand: Bryant, Payne
  • Product Family: PG97VTA
  • AFUE: 96.2-97
  • Air Flow Direction: Multi-Position
  • BTU Input: 52,000-80,000
  • BTU Output: 50,000-77,000
  • Blower Motor HP: 3/4
  • Blower Motor RPM: 600-1,200
  • Blower Motor Speeds: Variable
  • Blower Motor Type: ECM (Electronically Commutated Motor)
  • Blower Wheel Diameter: 11"
  • Blower Wheel Width: 8
  • Brand: Bryant, Payne
  • CFM: 255-1,625
  • CFM Heating: 1,135-1,290
  • Cabinet Width: 17.5
  • Color: Gray
  • Country Of Origin: USA
  • Cycle/Hertz: 60 Hz
  • Energy Star Rated: YES
  • FER Compliant: YES
  • Filter Size: 16" x 25" x 3/4
  • Fuel Type: Natural Gas or LP
  • Full Load Amps: 9.2
  • Furnace Type: Gas
  • Gas Connection Size: 1/2"
  • Gas Connection Type: NPT
  • Height: 35
  • Ignition Type: Hot Surface (HSI)
  • Includes Filter Rack: NO
  • Length: 29.5
  • Maximum Overcurrent Protection (MOCP): 15
  • OPT Code: 1PPG97VTAA48080B
  • Phase: Single
  • Prop 65: YES
  • Rated Load Amps (RLA): 9.2
  • Stages Heating: 2
  • UPC: See Optical
  • Voltage: 115 VAC
  • Weight: 150
  • Width: 17.5

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 216733617

AHRI 216733617 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**2517AM*.

Eligible Central HP <5.4 tons

AHRI 216734301

AHRI 216734301 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3017AM*.

Eligible Central HP <5.4 tons

AHRI 216734843

AHRI 216734843 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3617AM*.

Eligible Central HP <5.4 tons

AHRI 216735373

AHRI 216735373 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3717AM*.

Eligible Central HP <5.4 tons

AHRI 216736057

AHRI 216736057 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CAA**3721AM*.

Eligible Central HP <5.4 tons

AHRI 216737902

AHRI 216737902 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3012AM*.

Eligible Central HP <5.4 tons

AHRI 216738902

AHRI 216738902 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ24AA3 and indoor unit CSAH*3612AM*.

Eligible Central HP <5.4 tons

AHRI 217394174

AHRI 217394174 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ36AA3+TIC2025-0016 and indoor unit CAA**4821AM*.

Eligible Central HP <5.4 tons

AHRI 217394235

AHRI 217394235 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ36AA3+TIC2025-0016 and indoor unit CAA**4321AM*.

Eligible Central HP <5.4 tons

AHRI 217394296

AHRI 217394296 identifies a Mass Save qualified Central HP <5.4 tons from PAYNE HEATING AND COOLING with outdoor unit 37MUHAQ36AA3+TIC2025-0016 and indoor unit CAA**4221AM*.

Loading more

Service planning

How GreenFlow handles PG97VTAA48080B** requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Brands We Service

Popular cities

Service Areas

Our Happy Customers