Specifications

Product specifications

Product Type
Hybrid/Electric Heat Pump
Compressor Lower Ambient Cutoff (Boundary: lower, Operating Transition: compressor_to_resistance_only, Temperature Role: ambient)
37.4 degF
Compressor Upper Ambient Cutoff (Boundary: upper, Operating Transition: compressor_to_resistance_only, Temperature Role: ambient)
107.6 degF
Connected Capable
No
Fuel Type
Electric
Heat Pump Water Heater Form
240 Volt Integrated HPWH
Market Availability
Canada, United States
Maximum Current
24 A
Rated Electrical Input
4.9 kW
Refrigerant Type
R-134a
Refrigerant With Gwp Claim
R-134a (GWP:1430)
Storage Volume
46 gal_source
Supply Voltage
240 V
Tank Diameter
21.7 in
Tank Height
66.4 in
Time Of Use Schedule Capable
Yes
Annual Electricity Consumption (Draw Pattern: Medium-Usage)
844 kWh/year
Draw Pattern
Medium-Usage
First Hour Hot Water Delivery (Delivery Period: first_hour, Draw Pattern: Medium-Usage)
73 gal_source
Sound Pressure Level
49 dBA
Uniform Energy Factor (Draw Pattern: Medium-Usage)
3.75