Heat pump water heater

Back to State products

State HPSX-66-DHPT 2**

Category
Heat pump water heater
Series
Not assigned in catalog
Model record
Model pattern
Certifications
1 linked
State HPSX-66-DHPT 2** product image

Canonical product data

Specifications

Product specifications

Product Type
Hybrid/Electric Heat Pump
Communication Hardware Architecture
B - Manufacturer-specific external communication module (s) and/or device (s),C - Open standards-based communication port on the appliance with open standards-based communication module
Compressor Lower Ambient Cutoff (Boundary: lower, Operating Transition: compressor_to_resistance_only, Temperature Role: ambient)
37 degF
Connected Capable
Yes
Connects Using
CTA-2045
Demand Response Requires Broadband
Yes
Dr Protocol
CTA-2045-A, CTA-2045-B
Fuel Type
Electric
Heat Pump Water Heater Form
240 Volt Integrated HPWH
Load Up Functionality
Basic Load Up
Market Availability
United States
Maximum Current
22 A
Optional Operational Mode Functionality
Relative Price Signals, Set Point Adjustment
Rated Electrical Input
4.5 kW
Refrigerant Type
R-134a
Refrigerant With Gwp Claim
R-134a (GWP:1430)
Storage Volume
67 gal_source
Supply Voltage
240 V
Tank Diameter
23 in
Tank Height
61 in
Time Of Use Schedule Capable
Yes
Annual Electricity Consumption (Draw Pattern: High-Usage)
1233 kWh/year
Draw Pattern
High-Usage
First Hour Hot Water Delivery (Delivery Period: first_hour, Draw Pattern: High-Usage)
82 gal_source
Uniform Energy Factor (Draw Pattern: High-Usage)
3.7