Furnace
Tempstar N96MSN0802120A*D
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Model pattern
- Certifications
- 26 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 95 %
Matched systems
Certificates
25 verified catalog relationships.
AHRI 216677316
AHRI 216677316 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CURAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216735839
AHRI 216735839 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216737579
AHRI 216737579 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH24AAK and indoor unit ESH5X30M12A*.
AHRI 216738579
AHRI 216738579 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH24AAK and indoor unit ESH5X36M12A*.
AHRI 217396635
AHRI 217396635 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit EA*5X43M21A*.
AHRI 217397063
AHRI 217397063 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit EA*5X42M21A*.
AHRI 217397491
AHRI 217397491 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit EA*5X37M21A*.
AHRI 217488106
AHRI 217488106 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH36AAK+TIC2025-0016 and indoor unit EA*5X37M21A*.
Source-backed diagnostics
Error codes
32 codes matched to Tempstar N96MSN0802120A*D through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout - after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.