Furnace
Tempstar N96MSN1002122A*
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Model pattern
- Certifications
- 31 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 96.3 %
Matched systems
Certificates
30 verified catalog relationships.
AHRI 214158736
AHRI 214158736 identifies a HP - Split System from Tempstar with outdoor unit T5H6S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 214202584
AHRI 214202584 identifies a HP - Split System from Tempstar with outdoor unit N5H5S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 214202585
AHRI 214202585 identifies a HP - Split System from Tempstar with outdoor unit R5H5S24*K*AAA* and indoor unit EA*5X37M21A*.
AHRI 216677360
AHRI 216677360 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CURAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216735857
AHRI 216735857 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH24AAK and indoor unit EA*5X37M21A*.
AHRI 216738598
AHRI 216738598 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH24AAK and indoor unit ESH5X36M12A*.
AHRI 217395134
AHRI 217395134 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit ESH5X42M12A*.
AHRI 217396650
AHRI 217396650 identifies a Mass Save qualified HP - Split System from Tempstar with outdoor unit D5CUHAH30AAK+TIC2025-0016 and indoor unit EA*5X43M21A*.
Source-backed diagnostics
Error codes
32 codes matched to Tempstar N96MSN1002122A* through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout - after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.