Product troubleshooting

Back to TOSOT TM18D6MO

TOSOT TM18D6MO troubleshooting and error codes

These codes are matched from manufacturer documentation to this model's series or control platform. Keep checks visible and safe; do not open electrical, refrigerant, gas, combustion, or sealed equipment compartments.

Source-backed code set

52 matched codes

CodeMeaningSystem areaPriority
C5Jumper cap malfunctionIndoor control configurationService
E6Indoor-outdoor communication malfunctionCommunicationService
H5IPM protectionInverter power moduleUrgent
L3Outdoor fan or DC motor malfunctionOutdoor fanService
LAOutdoor fan or DC motor malfunctionOutdoor fanService
H3Compressor overload protectionCompressor protectionUrgent
F0Insufficient refrigerant or refrigerant cut-off protectionRefrigerant circuitUrgent
F1Indoor ambient temperature sensor open or short circuitIndoor ambient sensorService
F2Indoor evaporator temperature sensor open or short circuitIndoor evaporator sensorService
H6No feedback from indoor unit motorIndoor fan motorService
LPIndoor and outdoor unit capacity mismatchEquipment matchingService
C4Outdoor-unit jumper cap malfunctionOutdoor control configurationService
b7Gas-valve temperature sensor open or short circuitGas-valve temperature sensorService
b5Liquid-valve temperature sensor open or short circuitLiquid-valve temperature sensorService
E1System high-pressure protectionRefrigerant pressureUrgent
E3System or compressor low-pressure protectionRefrigerant pressureUrgent
E4Compressor high-discharge-temperature protectionCompressor discharge temperatureUrgent
E5AC overcurrent protectionElectrical currentUrgent
E7System mode conflictOperating modeService
E8High-temperature prevention protectionTemperature protectionUrgent
EEEEPROM malfunctionOutdoor control memoryService
FoRefrigerant recovery modeService modeNotice
F3Outdoor ambient temperature sensor open or short circuitOutdoor ambient sensorService
F4Outdoor condenser temperature sensor open or short circuitOutdoor condenser sensorService
F5Outdoor discharge temperature sensor open or short circuitOutdoor discharge sensorService
FCMicroswitch malfunctionSliding-door microswitchService
H4System abnormalSystem protectionUrgent
H7Compressor desynchronizationCompressor driveUrgent
HCPFC protectionPower factor correctionUrgent
HECompressor demagnetization protectionCompressorUrgent
JFIndoor unit and inspection-board communication malfunctionInspection-board communicationService
L1Humidity sensor malfunctionHumidity sensorService
L9High-power protectionPower protectionUrgent
LCStartup failedCompressor startupUrgent
LdLost phaseCompressor powerUrgent
oEUndefined outdoor-unit errorOutdoor unitService
P5Compressor over-phase-current protectionCompressor currentUrgent
P6Drive-board and main-board communication malfunctionOutdoor control communicationService
P7Module temperature-sensor circuit malfunctionModule temperature sensorService
P8Module overheating protectionInverter module temperatureUrgent
PFDrive-board ambient temperature sensor malfunctionDrive-board ambient sensorService
PHDC bus voltage too highDC bus voltageUrgent
PLDC bus voltage too lowDC bus voltageUrgent
PUCapacitor charging malfunctionInverter capacitor chargingService
rFRF module malfunctionRF moduleService
U1Phase-current detection circuit malfunctionCurrent detection circuitService
U2Compressor lost-phase protectionCompressor powerUrgent
U3DC bus voltage-drop malfunctionDC bus voltageUrgent
U5Unit current-detection malfunctionCurrent detectionService
U7Four-way valve abnormalReversing valveService
U8Indoor-unit zero-crossing signal malfunctionIndoor control power signalService
U9Outdoor-unit zero-crossing malfunctionOutdoor control power signalService