Product troubleshooting

Back to Trane 5TWR6018A1

Trane 5TWR6018A1 troubleshooting and error codes

These codes are matched from manufacturer documentation to this model's series or control platform. Keep checks visible and safe; do not open electrical, refrigerant, gas, combustion, or sealed equipment compartments.

Source-backed code set

9 matched codes

CodeMeaningSystem areaPriority
1 FlashAmbient temperature sensor out of rangeOutdoor ambient sensorService
2 FlashesCoil temperature sensor out of rangeOutdoor coil sensorService
3 FlashesLow pressure switch is openPressure safety circuitUrgent
4 FlashesHard lockoutDefrost control lockoutUrgent
5 FlashesSoft lockoutDefrost control lockoutService
6 FlashesDefrost cycles too close togetherDefrost operationService
7 FlashesTimed defrost mode: ambient sensor or reversing valve checkTimed defrost operationService
8 FlashesTimed defrost mode: coil sensor or reversing valve checkTimed defrost operationService
9 FlashesLow ambient soft lockoutLow ambient operationService