Source-backed code set
23 matched codes
| Code | Meaning | System area | Priority |
|---|---|---|---|
| E01 | Internal control failure | Integrated furnace control | Urgent |
| E2.1 | Retries exceeded; flame never sensed | Ignition and flame sensing | Urgent |
| E2.2 | Recycles exceeded; flame was lost | Ignition and flame sensing | Urgent |
| E2.3 | First-stage gas valve not energized when expected | Gas valve control | Urgent |
| E2.4 | HLO relay not energized when expected | Redundant relay / HLO output | Urgent |
| E3.1 | Pressure transducer signal not present | Pressure transducer | Urgent |
| E3.2 | Pressure transducer signal out of bounds | Pressure transducer | Urgent |
| E3.3 | Insufficient pressure | Pressure transducer | Urgent |
| E04 | Open limit switch | Thermal limit and safety circuit | Urgent |
| E05 | Flame sense error | Flame sensing | Urgent |
| E6.1 | Reversed polarity | Power and grounding | Urgent |
| E6.2 | Ground error | Power and grounding | Urgent |
| E7.1 | First-stage gas valve energized when it should be off | Gas valve control | Urgent |
| E7.2 | Redundant relay energized when it should be off | Redundant relay / HLO output | Urgent |
| E08 | Low flame sense | Flame sensing | Urgent |
| E10 | Inducer communication error | Inducer communication | Urgent |
| E11 | Internal gas valve error | Gas valve control | Urgent |
| E12 | Open low-voltage fuse | Low-voltage protection | Urgent |
| E13 | Personality module motor ID error | Motor identification | Urgent |
| E14 | Personality module missing | Configuration data | Urgent |
| E15 | Personality module memory error | Configuration data | Urgent |
| E17 | Blower communication error on motor | Blower communication | Urgent |
| E18 | Blower communication error on IFC | Blower communication | Urgent |