CodeMeaningSystem areaPriority
E01Internal control failureIntegrated furnace controlUrgent
E2.1Retries exceeded; flame never sensedIgnition and flame sensingUrgent
E2.2Recycles exceeded; established flame was lostIgnition and flame sensingUrgent
E2.3First-stage gas valve not energized when expectedGas valve controlUrgent
E3.1Shorted first-stage pressure switchPressure switch circuitUrgent
E3.2Open first-stage pressure switchPressure switch circuitUrgent
E3.3Shorted second-stage pressure switchPressure switch circuitUrgent
E3.4Open second-stage pressure switchPressure switch circuitUrgent
E4.0Open high limit switchThermal limit and safety circuitUrgent
E4.1Open reverse-airflow limit switchThermal limit and safety circuitUrgent
E4.2Open rollout limit switchThermal limit and safety circuitUrgent
E05Flame detected when it should not be presentFlame sensingUrgent
E6.1Reversed voltage polarityPower and groundingUrgent
E6.2Bad groundingPower and groundingUrgent
E6.3Igniter open or igniter relay failureIgnition circuitUrgent
E7.1First-stage gas valve energized without requestGas valve controlUrgent
E7.2Redundant relay energized when it should not beRedundant relay / HLO outputUrgent
E08Low flame senseFlame sensingUrgent
E11Internal gas valve errorGas valve controlUrgent
E12Open low-voltage fuseLow-voltage protectionUrgent
E13Blower HP or OEM ID mismatchBlower identificationUrgent
E14Configuration file errorConfiguration dataUrgent
E17Blower communication errorBlower communicationUrgent
E23Menu parameters not receivedControl communicationUrgent
E24Internal ACM/CCM communication errorControl communicationUrgent
E25Orientation sensor out of boundsOrientation sensorUrgent
E26Return static pressure transducer out of boundsReturn static pressure transducerUrgent
E27Return air thermistor out of boundsReturn air thermistorUrgent
E28Supply air thermistor out of boundsSupply air thermistorUrgent