What the code means
E24.1: ACM/CCM Modbus communication lost
The Trane S9V2 Link-enabled operation alarm table identifies E24.1 as communication lost between the ACM and CCM.
Troubleshooting code
Back to all S9V2 96 Two-Stage Variable Speed Gas Furnace error codes
ACM/CCM Modbus communication lost. Use this page to document the issue and prepare for service. GreenFlow should handle diagnosis for electrical, refrigerant, lockout, or recurring conditions.
What the code means
The Trane S9V2 Link-enabled operation alarm table identifies E24.1 as communication lost between the ACM and CCM.
Call GreenFlow if the code repeats, the system is locked out, heating or cooling is not restored, there is ice buildup, electrical odor, unusual noise, or any issue involving pressure switches, sensors, wiring, refrigerant, reversing-valve operation, or warranty coverage.
Share the visible code, model and serial number if available, photos, current symptoms, and whether the issue affects heating, cooling, or both.
The Trane S9V2 Link-enabled operation alarm table identifies E24.1 as communication lost between the ACM and CCM.
The Trane S9V2 Link-enabled operation alarm table associates E24.1 with "ACM/CCM Modbus communication lost".
This page uses the Trane S9V2 Link-enabled furnace alarm-code data set for S9V2 variable-speed gas furnaces.
The source-backed S9V2 row groups E24.1 under control communication.
Source-backed Trane FNR-SVN001A-EN Link-enabled furnace error-code table for S9V2 variable-speed furnaces.
This page is based on the S9V2 row where the code is "E24.1" and the Trane alarm message is "ACM/CCM Modbus communication lost".
Yes. The documented row pairs E24.1 with "ACM/CCM Modbus communication lost"; both the code and the message should be matched before using this page.
Yes. The source set for this record is the Trane S9V2 Link-enabled furnace alarm-code data set.
No. This record is tied to the S9V2 Link-enabled furnace data set. A different Trane product family should use its own documented alarm or error-code table.
The S9V2 row lists the system area for E24.1 as "Control communication".
No. The system area "Control communication" organizes the documented alarm row; it does not by itself identify every jobsite cause.
The Trane S9V2 Link-enabled operation alarm table identifies E24.1 as communication lost between the ACM and CCM.
The page connects the documented S9V2 alarm row to a specific stored Trane product, so the visible product model, code, and message stay together.
No. The code and message on this page come from the S9V2 Link-enabled furnace alarm table, so the exact S9V2 model and displayed code should be matched to the documented row.
No. The documented meaning for E24.1 should be read with the associated message "ACM/CCM Modbus communication lost" and the system area "Control communication".
No. The S9V2 alarm table separates individual codes. This page is for E24.1, which the source-backed row defines as "ACM/CCM Modbus communication lost".
Match the furnace family, the visible alarm code, and the exact alarm message to the documented S9V2 row before using this page as service-prep context.
That wording comes from the Trane S9V2 alarm-code row. It is the system area used to organize the documented E24.1 condition.
The Trane source row identifies this as a communication-related condition. Preserve the displayed code and any companion alert text before clearing or resetting controls.
The Trane source row points to control communication. Record the exact code and visible alert text before any reset so the control history is not lost.
Capture the exact code, any displayed alert text, the model and serial number, thermostat or control status, operating mode, symptoms, and photos of the display or LED pattern before the alert history is cleared.