Product troubleshooting

Back to Trane S9V2C080U5PSC

Trane S9V2C080U5PSC troubleshooting and error codes

These codes are matched from manufacturer documentation to this model's series or control platform. Keep checks visible and safe; do not open electrical, refrigerant, gas, combustion, or sealed equipment compartments.

Source-backed code set

40 matched codes

CodeMeaningSystem areaPriority
E1.0Internal failureIntegrated furnace controlUrgent
E2.1Retry exceededIgnition and flame sensingUrgent
E2.2Recycles exceededIgnition and flame sensingUrgent
E2.3First-stage gas valve not energized when expectedGas valve controlUrgent
E3.1Shorted first-stage pressure switchPressure switch circuitUrgent
E3.2Open first-stage pressure switchPressure switch circuitUrgent
E3.3Shorted second-stage pressure switchPressure switch circuitUrgent
E3.4Open second-stage pressure switchPressure switch circuitUrgent
E3.5Open second-stage pressure switch with second-stage gas valve energizedPressure switch circuitUrgent
E4.0Open high limitThermal limit and safety circuitUrgent
E4.1Open reverse-airflow limitThermal limit and safety circuitUrgent
E4.2Open rollout limitThermal limit and safety circuitUrgent
E5.0Flame sensed when no flame should be presentFlame sensingUrgent
E6.1Reversed voltage polarityPower and groundingUrgent
E6.2Bad groundingPower and groundingUrgent
E6.3Igniter failureIgnition circuitUrgent
E7.1First-stage gas valve energized without requestGas valve controlUrgent
E7.2Redundant relay energized when it should be offRedundant relay / HLO outputUrgent
E8.0Low flame senseFlame sensingUrgent
E9.1Open inducer limit switchInducer safety circuitUrgent
E9.2Open condensate pressure switchCondensate safety circuitUrgent
E9.3Condensate lockoutCondensate safety circuitUrgent
E9.4Furnace control mismatchControl compatibilityUrgent
E10.1VSIM motor-control communication errorMotor communicationUrgent
E10.4VSDI control or motor failureVariable-speed inducer controlUrgent
E11Internal gas valve errorGas valve controlUrgent
E12Open low-voltage fuseLow-voltage protectionUrgent
E13Blower HP or OEM ID mismatchBlower identificationUrgent
E14Configuration data errorConfiguration dataUrgent
No modelNo model number programmedConfiguration dataUrgent
Invalid modelInvalid model numberConfiguration dataUrgent
E17Blower motor communication errorBlower communicationUrgent
E18Blower control communication errorBlower communicationUrgent
E23Incomplete menu dataControl communicationUrgent
E24.1ACM/CCM Modbus communication lostControl communicationUrgent
E24.2CAN communication lostControl communicationUrgent
E25Accelerometer out of boundsOrientation sensorUrgent
E26Return static pressure transducer out of rangeReturn static pressure transducerUrgent
E27Return thermistor out of rangeReturn thermistorUrgent
E28Supply thermistor out of rangeSupply thermistorUrgent