Troubleshooting · AirquestAirquest N96MSN1202422A**D 12.1W on at power up
Troubleshooting · AirquestAirquest N96MSN1202422A**D 10.1L1 polarity fault
Troubleshooting · AirquestAirquest N96MSN1002122A 25.6Wrong program for control used
Troubleshooting · AirquestAirquest N96MSN0801716A* 33.1A switch has opened in the Main Limit circuit
Troubleshooting · AirquestAirquest N96MSN0601716A 14.1Ignition lockout - after 4 consecutive ignition tries
Troubleshooting · AirquestAirquest N96MSN1002122A* 45.3Control failure - EEPROM memory issue
Troubleshooting · AirquestAirquest N96MSN0601716A 13.1Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Troubleshooting · AirquestAirquest N96MSN0801716A* 25.1No program info in micro, no heating operation
Troubleshooting · AirquestAirquest N96MSN0601716A* 25.2Corrupted program file, reprogram control using service app or super plug
Troubleshooting · AirquestAirquest N96MSN0401410A*D 45.3Control failure - EEPROM memory issue
Troubleshooting · AirquestAirquest N96MSN0801716A**D 31.2Open secondary pressure switch (HPS)
Troubleshooting · AirquestAirquest N96MSN0802120A 14.3Lockout - 7 loss of flame events during a heat request